Description
The device comes with part numbers 780114-01, 780114-04, and 779628-01, designed to cater to a range of requirements. It features a 16-bit resolution, ensuring high-quality data output for precise applications.
For versatile application needs, it supports both Analog Triggering and Digital Triggering types. The device is equipped with two 32-bit, 80 MHz counters/timers, enhancing its functionality in time-sensitive operations.
It offers 32 single-ended or 16 differential Analog Input Channels, providing flexibility in connecting various sensors or signals. Furthermore, the device boasts a maximum sample rate of 1.25 MS/s per channel, ensuring efficient data acquisition and processing.
The device also includes 4 Analog Output Channels and supports Four High-Speed, Signal Streaming Data Streams, enabling robust data output capabilities. With NI-MCal Calibration Technology, it assures accurate performance over its service life.
It is compatible with Windows Vista, Windows XP, and Windows 2000 operating systems, ensuring broad compatibility with existing computer systems. A recommended warm-up time of 30 minutes is advised for optimal performance, and it is recommended to undergo calibration at least once every 2 years.
The device is compatible with the NI-SCC signal conditioning platform, offering extended functionality. For connectivity, it features a USB 2.0 Hi-Speed or full-speed bus interface, ensuring easy and reliable connection to PCs. Its physical dimensions are 10.5 x 6.73 x 1.75 inches (Screw Terminal), making it a compact addition to any setup.
| Specification | Detail |
|---|---|
| Part Numbers | 780114-01, 780114-04, 779628-01 |
| Resolution | 16-bit |
| Triggering Types | Analog Triggering, Digital Triggering |
| Counters/Timers | Two 32-bit, 80 MHz |
| Analog Input Channels | 32 single-ended or 16 differential |
| Maximum Sample Rate (per channel) | 1.25 MS/s |
| Analog Output Channels | 4 |
| Data Streams | Four High-Speed, Signal Streaming |
| Calibration Technology | NI-MCal |
| Supported Operating Systems | Windows Vista, Windows XP, Windows 2000 |
| Recommended Warm-up Time | 30 minutes |
| Recommended Calibration Period | At least once every 2 years |
| Compatibility | NI-SCC signal conditioning platform |
| Interface | USB 2.0 Hi-Speed or full-speed bus |
| Physical Dimensions (Screw Terminal) | 10.5 x 6.73 x 1.75 in.
Question 1: What resolution does the USB-6259 offer? Answer 1: 16-bit resolution Question 2: What type of connectivity does the USB-6259 use? Question 3: How many analog input channels does the USB-6259 have? Question 4: What is the max sample rate per channel for the USB-6259? Question 5: How often should the USB-6259 be calibrated? |