img

780055-03

This device offers Hi-Speed USB interface, 30-minute warm-up, 2-year calibration, supports various signal streams, and features overvoltage protection.

In Stock | Ships Today

img

    Description

    The product comes with a variety of part numbers including 780055-01, 780056-06, 780056-01, 780055-04, and 780056-04, ensuring a range of options for diverse requirements. It features a Hi-Speed USB interface for efficient data transfer and connectivity. Users need to allow a 30 minutes warm-up time for optimal performance. The device is designed for durability and long-term use, with a calibration interval of every 2 years.

    The maximum working voltage is specified at 11 V (signal + common mode voltage), accommodating various operational needs. It requires a power supply within the range of 11 to 30 VDC, offering flexibility in power sources. The device supports 4 signal streams including Analog Input/Output and Digital Input/Output, enhancing its utility in multiple scenarios.

    Equipped with 2 general-purpose counters/timers that boast a 32-bit resolution, it ensures precise timing and counting capabilities. The counter base clock frequencies are quite versatile, offering internal frequencies of 80 MHz, 20 MHz, and 0.1 MHz, and an external range from 0 MHz to 20 MHz.

    An advanced analog trigger system is included, featuring 10-bits resolution, along with Analog Edge and Analog Window Triggering options, providing flexibility in triggering mechanisms. The device supports up to 16 differential or 32 single-ended analog input channels, with an 18-bits ADC resolution, and 4 analog output channels with a 16-bits DAC resolution, ensuring high-quality data acquisition and output.

    The sample rate for a single channel can reach up to 625 kS/s, and for multiple channels, it is up to 500 kS/s, allowing for efficient data sampling. Lastly, it boasts

    Specification Description
    Part Numbers 780055-01, 780056-06, 780056-01, 780055-04, 780056-04
    Interface Hi-Speed USB
    Warm-up Time 30 minutes
    Calibration Interval 2 years
    Maximum Working Voltage 11 V (signal + common mode voltage)
    Power Supply Requirement 11 to 30 VDC
    Signal Streams 4 (Analog Input/Output, Digital Input/Output)
    Counters/Timers 2 general-purpose, 32-bit resolution
    Counter Base Clock Frequencies Internal: 80 MHz, 20 MHz, 0.1 MHz; External: 0 MHz to 20 MHz
    Analog Trigger 1, 10-bits resolution, Analog Edge Triggering, Analog Window Triggering
    Analog Input Channels 16 differential or 32 single-ended, 18-bits ADC resolution
    Analog Output Channels 4, 16-bits DAC resolution
    Sample Rate (Single Channel) 625 kS/s
    Sample Rate (Multiple Channels) 500 kS/s
    Overvoltage Protection All analog input and sense channels

    Question 1: What is the warm-up time for USB-6289?
    Answer 1: 30 minutes

    Question 2: What is the calibration interval for the USB-6289?
    Answer 2: 2 years

    Question 3: What are the counter base clock internal frequencies of USB-6289?
    Answer 3: 80 MHz, 20 MHz, 0.1 MHz

    Question 4: What is the maximum working voltage for USB-6289?
    Answer 4: 11 V

    Question 5: What is the sample rate for a single channel on the USB-6289?
    Answer 5: 625 kS/s