img

780055-04

The USB-6289 is a PC-based multifunction DAQ with 32 analog inputs, 48 DIO, 4 outputs, Hi-Speed USB, requiring 11-30 VDC, and a 2-year calibration interval.

In Stock | Ships Today

img

    Description

    The product with the part number 780055-04 falls under the category of PC-based Multifunction DAQ. It is identified as model USB-6289. This model is described as a USB-6289 M Series DAQ which includes 32 500 kS/s Analog Inputs, 48 Digital I/O, 4 Analog Outputs with a Screw Terminal connection method.

    This DAQ device uses a Hi-Speed USB connection for interfacing. Regarding operational readiness, it requires a warm-up time of 30 minutes. For maintenance and accuracy, a calibration interval of 2 years is recommended. The maximum working voltage for this device is specified as 11 V, and it requires a power supply within the range of 11 to 30 VDC.

    It supports four signal streams and is equipped with two general-purpose counters/timers that have a 32-bit resolution. For frequency needs, it offers base clock frequencies (internal) of 80 MHz, 20 MHz, and 0.1 MHz, and it can accept an external base clock frequency ranging from 0 MHz to 20 MHz.

    The device also includes one analog trigger with a 10-bits resolution and supports triggering modes such as Analog Edge Triggering and Analog Window Triggering.

    Question 1: What is the part number for the USB-6289?
    Answer 1: 780055-04

    Question 2: How many analog inputs does the USB-6289 have?
    Answer 2: 32

    Question 3: What is the recommended calibration interval for USB-6289?
    Answer 3: 2 years

    Question 4: What power supply range does the USB-6289 require?
    Answer 4: 11 to 30 VDC

    Question 5: Can the USB-6289 accept an external base clock frequency?
    Answer 5: Yes, 0 MHz to 20 MHz

    Specification Detail
    Part Number 780055-04
    Category PC-based Multifunction DAQ
    Model USB-6289
    Description USB-6289 M Series DAQ (32 500 kS/s Analog Inputs, 48 Digital I/O, 4 Analog Outputs) Screw Term
    Connection Hi-Speed USB
    Warm-up Time 30 minutes
    Calibration Interval 2 years
    Maximum Working Voltage 11 V
    Power Supply Requirement 11 to 30 VDC
    Signal Streams Four
    Counters/Timers Two general-purpose, 32-bit resolution
    Base Clock Frequencies (Internal) 80 MHz, 20 MHz, 0.1 MHz
    Base Clock Frequency (External) 0 MHz to 20 MHz
    Analog Trigger One, 10-bits resolution
    Triggering Modes Analog Edge Triggering, Analog Window Triggering