Description
The USB-6289 is a sophisticated PC-based Multifunction DAQ designed for a wide range of applications. With a part number of 780056-07, this device stands out for its versatility and high performance in data acquisition tasks.
It boasts an impressive array of 32 500 kS/s Analog Inputs, alongside 48 Digital I/O, and 4 Analog Outputs, making it a comprehensive solution for mass termination applications. The USB-6289 connects via Hi-Speed USB, ensuring reliable and fast data transfer rates for all your project needs.
Before reaching optimal performance, the device requires a warm-up time of 30 minutes. It is recommended to calibrate the device every 2 years to maintain its precision and accuracy. With a maximum working voltage of 11 V and a power supply requirement ranging from 11 to 30 VDC, it accommodates a variety of operational environments.
The USB-6289 features 4 signal streams and includes 2 general-purpose, 32-bit resolution counters/timers, enhancing its utility for complex timing and counting tasks. Its internal base clocks are set at 80 MHz, 20 MHz, and 0.1 MHz, with the capability to accept an external base clock frequency ranging from 0 MHz to 20 MHz. This flexibility allows for precise timing adjustments according to specific application needs.
An additional feature is its analog trigger, which has a 10-bits resolution, providing high-precision triggering capabilities. The device supports up to 16 differential or 32 single-ended analog input channels, offering extensive monitoring and data collection capabilities.
In summary, the USB-6289 M Series DAQ device is a highly versatile and powerful tool for professionals requiring a reliable PC-based multifunction DAQ system. Its comprehensive specifications and capabilities make it ideal for a wide range of applications, from industrial monitoring to laboratory research.
| Specification | Details |
|---|---|
| Part Number | 780056-07 |
| Category | PC-based Multifunction DAQ |
| Model | USB-6289 |
| Description | USB-6289 M Series DAQ (32 500 kS/s Analog Inputs, 48 Digital I/O, 4 Analog Outputs) Mass Term |
| Connection | Hi-Speed USB |
| Warm-up Time | 30 minutes |
| Calibration Interval | 2 years |
| Maximum Working Voltage | 11 V |
| Power Supply Requirement | 11 to 30 VDC |
| Signal Streams | 4 |
| Counters/Timers | 2 general-purpose, 32-bit resolution |
| Internal Base Clocks | 80 MHz, 20 MHz, 0.1 MHz |
| External Base Clock Frequency | 0 MHz to 20 MHz |
| Analog Trigger | 1, 10-bits resolution |
| Analog Input Channels | 16 differential or 32 single-ended |