The National Instruments USB-6525 Digital I/O Device, with Part Number 779640-01, is designed for a variety of data acquisition tasks, featuring 8 isolated digital input channels operating at ±60 VDC and 8 isolated solid-state relay (SSR) outputs that handle up to 60 VDC and 30 Vrms.
It boasts a counter capable of 5 kHz frequency with a 32-bit resolution, and the M-Series mainboard enhances its data acquisition capabilities. For analog inputs, the device provides 18-bit accuracy, ensuring precise measurements.
Incorporated programmable low-pass filters help in minimizing high-frequency noise and blocking aliasing, while the change detection feature allows for programmable interruption, signaling changes with a propagation delay of 65 µs for isolated inputs and a minimum pulse width for change detection of 200 µs.
The SSR outputs can switch a maximum current of 500 mA, and the device’s weight varies between 2.3 oz and 3.1 oz depending on whether connectors are attached. The physical dimensions are 2.50 x 3.35 x 0.91 inches without connectors and 3.22 x 3.35 x 0.91 inches with connectors, making it a compact and robust tool for various applications.
Feature | Specification |
---|---|
Product Name | National Instruments USB-6525 Digital I/O Device |
Part Number | 779640-01 |
Input Channels | 8 digital channels, ±60 VDC, isolated |
Output Channels | 8 SSR outputs, isolated, 60 VDC, 30 Vrms |
Counter | 5 kHz frequency, 32-bit resolution |
Mainboard | M-Series, used for data acquisition |
Analog Input Accuracy | 18-bits |
Filters | Programmable low-pass filters |
Change Detection | Yes, with programmable interruption |
Propagation Delay | 65 µs for isolated inputs |
Minimum Pulse Width for Change Detection | 200 µs for isolated inputs |
Maximum Switching Current (SSR outputs) | 500 mA |
Weight | 2.3 oz (without connectors), 3.1 oz (with connectors) |
Physical Dimensions (W x D x H) | 2.50 x 3.35 x 0.91 in. (without connectors), 3.22 x 3.35 x 0.91 in |
Question 1: What is the function of the programmable low-pass filters in the National Instruments USB-6525 Digital I/O Device?
Answer 1: The programmable low-pass filters in the National Instruments USB-6525 Digital I/O Device serve to minimize high-frequency noise and prevent aliasing, ensuring cleaner signal acquisition and more accurate measurements.
Question 2: What is the weight range and the physical dimensions of the National Instruments USB-6525 Digital I/O Device with and without connectors?
Answer 2: The weight of the National Instruments USB-6525 Digital I/O Device ranges from 2.3 oz to 3.1 oz, and its physical dimensions are 2.50 x 3.35 x 0.91 inches without connectors and 3.22 x 3.35 x 0.91 inches with connectors.
Question 3: What is the frequency and bit resolution of the counter on the National Instruments USB-6525 Digital I/O Device, and what are its physical dimensions with and without connectors?
Answer 3: The counter on the National Instruments USB-6525 Digital I/O Device operates at a frequency of 5 kHz and has a 32-bit resolution, and its physical dimensions are 2.50 x 3.35 x 0.91 inches without connectors and 3.22 x 3.35 x 0.91 inches with connectors.
Question 4: What are the voltage capabilities of the isolated digital input channels and solid-state relay outputs on the National Instruments USB-6525 Digital I/O Device with Part Number 779640-01?
Answer 4: The isolated digital input channels on the National Instruments USB-6525 Digital I/O Device with Part Number 779640-01 operate at ±60 VDC, and the solid-state relay (SSR) outputs can handle up to 60 VDC and 30 Vrms.
Question 5: What is the maximum current that the solid-state relay outputs of the National Instruments USB-6525 Digital I/O Device can switch, and how do its physical dimensions vary with and without connectors?
Answer 5: The solid-state relay outputs of the National Instruments USB-6525 Digital I/O Device can switch a maximum current of 500 mA, and its physical dimensions are 2.50 x 3.35 x 0.91 inches without connectors and 3.22 x 3.35 x 0.91 inches with connectors.