Description
The USB-6366 is a PC-based Multifunction DAQ designed to meet a wide range of automation and processing tasks. This device is part of a series with part numbers including 781445-01, 782264-01, 781445-02, 782263-01, and 782262-01. It is equipped with 8 differential analog input channels that can handle voltages up to ±11 V across all ranges, ensuring versatile data acquisition capabilities.
In addition to its analog inputs, the USB-6366 features 2 analog output channels and 24 bidirectional digital I/O channels, providing ample connectivity for various sensors and actuators. This device also includes 4 counters/timers, enhancing its ability to manage complex timing and counting tasks efficiently.
The analog input FIFO buffer size of the USB-6366 can be either 32 MS or 64 MS, which allows for efficient data management during high-speed data acquisition. The frequency generator supports divisors from 1-16, with a frequency range of 100 kHz to 20 MHz, offering precise control over frequency generation for a variety of applications.
Before reaching optimal performance, the USB-6366 requires a warm-up time of 15 minutes. It is recommended that the device undergoes calibration every 2 years to maintain accuracy and reliability. The maximum working voltage is rated at 11 V (Category I), ensuring safety during operation.
The operating humidity range for the USB-6366 is 10% to 90% (noncondensing), and the storage humidity range is 5% to 95% (noncondensing). These specifications ensure that the device can perform reliably in a variety of environmental conditions without condensation issues.
| Specification | Detail |
|---|---|
| Part Numbers | 781445-01, 782264-01, 781445-02, 782263-01, 782262-01 |
| Category | PC-based Multifunction DAQ |
| Model | USB-6366 |
| Analog Input Channels | 8 differential |
| Analog Input Voltage | ±11 V for all ranges |
| Analog Output Channels | 2 |
| Digital I/O Channels | 24 bidirectional |
| Counters/Timers | 4 |
| Analog Input FIFO Buffer Size | 32 MS or 64 MS |
| Frequency Generator Divisors | 1-16 |
| Frequency Range | 100 kHz to 20 MHz |
| Warm-up Time | 15 minutes |
| Calibration Interval | Every 2 years |
| Maximum Working Voltage | 11 V (Category I) |
| Operating Humidity Range | 10% to 90% (noncondensing) |
| Storage Humidity Range | 5% to 95% (noncondensing) |
Question 1: What is the max voltage for the USB-6366’s analog inputs?
Answer 1: ±11 V
Question 2: How often does the USB-6366 need recalibration?
Answer 2: Every 2 years
Question 3: What is the analog input FIFO buffer size of the USB-6366?
Answer 3: 32 MS or 64 MS
Question 4: What is the USB-6366’s warm-up time for optimal performance?
Answer 4: 15 minutes
Question 5: What frequency range can the USB-6366’s generator support?
Answer 5: 100 kHz to 20 MHz