Description
The 193362E-01L (Alternate: 782002-01) is a part of the VXI Remote Controllers category, specifically the VXI-8360LT model. This model is a Remote Control Module designed for VXI systems, utilizing MXI-Express technology. It requires one VXI C-size slot for installation.
The front panel of the VXI-8360LT includes three SMB type connectors, which are used for Trigger Input, Trigger Output, and CLK10 I/O signals, ensuring flexible connection options. One of the notable features of this module is its daisy-chain capability, allowing for the integration of up to 8 CLK10 and/or TTL triggers, enhancing its utility in complex setups.
For troubleshooting and maintenance, the VXI-8360LT is equipped with an integrated EEPROM and supports the Resman diagnostic utility, facilitating easy management and diagnostic processes. Its design ensures operation readiness within 5 seconds after a system reset, minimizing downtime and ensuring efficient performance.
The module’s CLK10 sources can be derived from an internal oscillator or an EXT CLK connector, providing flexibility in synchronization and timing across VXI systems. This makes the VXI-8360LT an essential component for users seeking a high-performing, reliable remote control module for their VXI framework.
| Specification | Details |
|---|---|
| Part Number | 193362E-01L (Alternate: 782002-01) |
| Category | VXI Remote Controllers |
| Model | VXI-8360LT |
| Type | Remote Control Module for VXI |
| Technology | MXI-Express |
| Slot Requirement | One VXI C-size slot |
| Front Panel Connectors | Three SMB type (Trigger Input, Trigger Output, CLK10 I/O signals) |
| Daisy-Chain Capability | Yes, up to 8 CLK10 and/or TTL triggers |
| Diagnostic Utility | Resman |
| EEPROM | Integrated |
| Operation Readiness | Within 5 seconds after a system reset |
| CLK10 Sources | Internal oscillator, EXT CLK connector |
Question 1: What is the part number of VXI-8360LT?
Answer 1: 193362E-01L, alternate 782002-01.
Question 2: How quickly does VXI-8360LT become operational after reset?
Answer 2: Within 5 seconds.
Question 3: How many SMB connectors does the VXI-8360LT have?
Answer 3: Three.
Question 4: Can the VXI-8360LT module be daisy-chained?
Answer 4: Yes, up to 8 CLK10 and/or TTL triggers.
Question 5: What technology does VXI-8360LT use?
Answer 5: MXI-Express.