img

PXI-6040E

The National Instruments PXI-6040E Multifunction DAQ is a 12-bit data acquisition device with 16 single-ended or 8 differential analog input channels, a 500 kS/s maximum sampling rate, LabVIEW integration, and

In Stock | Ships Today

img

    Description

    The National Instruments PXI-6040E Multifunction DAQ, with part numbers 777484-01 and 184361A-01, is a high-resolution 12-Bit data acquisition system. It offers a versatile set of analog input channels, providing users with either 16 single-ended or 8 differential options, and can operate at a maximum sampling rate of 500 kS/s. With 2 analog outputs, the PXI-6040E is equipped for a variety of data handling tasks.

    Integration with LabVIEW and support from the comprehensive NI-DAQmx driver allows for seamless software interaction. This device stands out with its measurement sensitivity of 0.008 mV, ensuring precise readings. The robust 68-pin male 0.050 D-type I/O Connector ensures reliable physical connections, while the 10 kΩ impedance for the external trigger input accommodates a broad range of signal sources.

    The PXI-6040E supports various input modes, including non-referenced single-ended, differential single-ended, and referenced single-ended (RSE), catering to different signal conditioning requirements. The onboard NI PGIA (Programmable Gain Instrumentation Amplifier) is designed for optimal signal amplification, ensuring the integrity of measurements even at high gains. For best performance, a recommended warm-up time of 15 minutes is suggested, and it is advised to perform calibration at least once a year to maintain accuracy.

    Question 1: What are the specific features and capabilities of the National Instruments PXI-6040E Multifunction DAQ that enable it to offer precise and versatile data acquisition?
    Answer 1: The recommended 15-minute warm-up time for the National Instruments PXI-6040E Multifunction DAQ ensures that the device reaches a stable operating temperature, which is crucial for maintaining measurement accuracy and optimal performance.

    Question 2: What are the specifications and software compatibility features of the National Instruments PXI-6040E Multifunction DAQ, and what measures are recommended to ensure optimal performance and measurement accuracy?
    Answer 2: The National Instruments PXI-6040E Multifunction DAQ is characterized by its 12-Bit high-resolution data acquisition system, with the flexibility of 16 single-ended or 8 differential analog input channels, a maximum sampling rate of 500 kS/s, and 2 analog outputs. Its integration with LabVIEW, support from NI-DAQmx driver, a measurement sensitivity of 0.008 mV, and a variety of input modes including non-referenced single-ended,

    Question 3: What is the impact of the recommended 15-minute warm-up time on the performance of the National Instruments PXI-6040E Multifunction DAQ?
    Answer 3: The measurement sensitivity of the National Instruments PXI-6040E Multifunction DAQ is 0.008 mV, and it is recommended to perform calibration at least once a year to maintain accuracy.

    Question 4: What are the features and technical specifications that define the National Instruments PXI-6040E Multifunction DAQ’s capabilities in data acquisition and signal processing?
    Answer 4: The National Instruments PXI-6040E Multifunction DAQ is a 12-Bit data acquisition system with part numbers 777484-01 and 184361A-01, featuring 16 single-ended or 8 differential analog input channels, a maximum sampling rate of 500 kS/s, and 2 analog outputs. It integrates seamlessly with LabVIEW, is supported by the NI-DAQmx driver, boasts a measurement sensitivity of 0.008 mV, and includes

    Question 5: What is the measurement sensitivity of the National Instruments PXI-6040E Multifunction DAQ and how often is it recommended to perform calibration to maintain accuracy?
    Answer 5: The National Instruments PXI-6040E Multifunction DAQ features a high-resolution 12-bit data acquisition system, 16 single-ended or 8 differential analog input channels, a maximum sampling rate of 500 kS/s, 2 analog outputs, and a measurement sensitivity of 0.008 mV, along with integration with LabVIEW and NI-DAQmx driver support for software interaction. It also includes a robust 68-pin male 0.050 D-type I/O connector

    Specification Detail
    Manufacturer National Instruments
    Product PXI-6040E Multifunction DAQ
    Part Numbers 777484-01, 184361A-01
    Resolution 12-Bit
    Analog Input Channels 16 single-ended or 8 differential
    Maximum Sampling Rate 500 kS/s
    Analog Outputs 2
    Software LabVIEW Integration, NI-DAQmx driver
    Measurement Sensitivity 0.008 mV
    I/O Connector 68-pin male 0.050 D-type
    External Trigger Impedance 10 kΩ
    Input Modes Non-referenced single-ended, Differential single-ended, Referenced single-ended (RSE)
    Amplifier NI PGIA (Programmable Gain Instrumentation Amplifier)
    Recommended Warm-up Time 15 minutes
    Calibration At least once a year