img

189718Y-03

The PXI-5610 is a 2-slot, 3U PXI RF upconverter module with a frequency range of 250 kHz to 2.7 GHz and a 130 dB flexible gain.

In Stock | Ships Today

img

    Description

    The part number 778737-01 identifies a specific model of RF Upconverters, known as the PXI-5610. This device is designed to fit within a 2-slot, 3U PXI module, making it a compact and efficient solution for a variety of applications. The PXI-5610 operates over a wide frequency range from 250 kHz to 2.7 GHz, and offers a 20 MHz continuous bandwidth.

    Its output power range is quite versatile, spanning from -145 dBm to +10 dBm, and it boasts a 130 dB flexible gain, allowing for a broad range of signal processing capabilities. The device’s timebase stability is ensured by a high-stability OCXO, with a precision of ±50 ppb, ensuring reliable performance.

    The PXI-5610 is compatible with Windows 2000/NT/XP operating systems and supports programming through LabVIEW and LabWindows/CVI driver software, providing flexibility in application development. It can utilize reference clock sources from a high-accuracy OCXO, an external reference clock, or the PXI backplane, offering multiple options for timing synchronization.

    A calibration interval is recommended annually or every two years to maintain accuracy and performance. The unit weighs 41.1 oz. and has dimensions of 8.5 x 1.6 x 5.2 in, making it a manageable size for most setups. It operates efficiently within a temperature range of 0 °C to 55 °C, with a warm-up time of approximately 30 minutes before reaching optimal performance levels.

    Specification Details
    Part Number 778737-01
    Category RF Upconverters
    Model PXI-5610
    Form Factor 2-slot, 3U PXI module
    Frequency Range 250 kHz to 2.7 GHz
    Bandwidth 20 MHz continuous
    Output Power Range -145 dBm to +10 dBm
    Gain 130 dB flexible
    Timebase Stability High-stability OCXO, ±50 ppb
    Operating System Compatibility Windows 2000/NT/XP
    Driver Software LabVIEW, LabWindows/CVI
    Reference Clock Sources High-accuracy OCXO, external reference clock, PXI backplane
    Calibration Interval Recommended annually or every two years
    Weight 41.1 oz.
    Dimensions 8.5 x 1.6 x 5.2 in
    Temperature Range 0 °C to 55 °C
    Warm-up Time 30 minutes

    Question 1: What is the frequency range of the PXI-5610?
    Answer 1: 250 kHz to 2.7 GHz

    Question 2: How many slots does the PXI-5610 occupy?
    Answer 2: 2-slot, 3U PXI module

    Question 3: What is the output power range of the PXI-5610?
    Answer 3: -145 dBm to +10 dBm

    Question 4: What is the timebase stability precision of the PXI-5610?
    Answer 4: ±50 ppb

    Question 5: What operating systems is the PXI-5610 compatible with?
    Answer 5: Windows 2000/NT/XP