Description
The National Instruments NI-9244 with part number 783106-01 is equipped with a high-precision 24-bit Delta-Sigma ADC per channel and supports three single-ended, simultaneously sampled AI channels. With an impressive sample rate of 50 kS/s per channel and a substantial analog input range of 800 Vrms L-L, this module ensures accurate and expansive data acquisition capabilities.
Designed for reliable connectivity, the module features screw-terminal connections and boasts a maximum input noise of 6 mVrms. It incorporates both digital and analog filters for signal clarity, and supports DC input coupling to accommodate a variety of measurement needs.
With an input impedance of 2 MΩ for both Neutral-to-Ground and AIx-to-Ground, the NI-9244 ensures compatibility with a range of signal sources. It also provides robust protection against electrical stress with 800 Vrms continuous overvoltage protection, capable of handling up to 1000 Vrms for 1 second, and can withstand voltage surges of 8 kV for 1.2 µs/50 µs.
The module operates using the versatile NI-DAQmx driver software, which is compatible with several development environments including LabVIEW, LabWindows/CVI, ANSI C, and .NET, making integration into existing systems seamless. Despite its high functionality, the NI-9244 maintains a low power consumption of 332 mW maximum when active, and a mere 50 µW when in sleep mode, highlighting its efficiency.
Specification | Detail |
---|---|
Part Number | 783106-01 |
ADC Type | 24-bit Delta-Sigma per channel |
Number of Channels | Three single-ended, simultaneously sampled AI channels |
Sample Rate | 50 kS/s per channel |
Analog Input Range | 800 Vrms L-L |
Connectivity | Screw-terminal |
Input Noise (Max) | 6 mVrms |
Filtering | Digital and analog filters |
DC Input Coupling | Supported |
Input Impedance (Neutral-to-Ground, AIx-to-Ground) | 2 MΩ |
Overvoltage Protection | 800 Vrms continuous, 1000 Vrms for 1 s |
Surge Withstand | 8 kV for 1.2 µs/50 µs |
Driver Software | NI-DAQmx, compatible with LabVIEW, LabWindows/CVI, ANSI C, .NET |
Power Consumption | 332 mW max active, 50 µW sleep mode |
Question 1: How does the National Instruments NI-9244 mitigate potential electrical stress on the system, and what is its continuous overvoltage protection rating?
Answer 1: The National Instruments NI-9244 mitigates potential electrical stress by offering robust protection features, including an 800 Vrms continuous overvoltage protection, the ability to handle up to 1000 Vrms for 1 second, and the capacity to withstand voltage surges of 8 kV for 1.2 µs/50 µs.
Question 2: What is the input impedance value for both Neutral-to-Ground and AIx-to-Ground on the National Instruments NI-9244 data acquisition module?
Answer 2: The input impedance for both Neutral-to-Ground and AIx-to-Ground on the National Instruments NI-9244 data acquisition module is 2 MΩ.
Question 3: What are the key data acquisition capabilities and protection features of the National Instruments NI-9244 module with part number 783106-01?
Answer 3: The National Instruments NI-9244 module offers several advantages in terms of data acquisition capabilities, connectivity, and protection against electrical stress, such as high-precision 24-bit Delta-Sigma ADCs per channel for accurate readings, simultaneous sampling of three single-ended AI channels at a sample rate of 50 kS/s per channel, and an extensive analog input range of 800 Vrms L-L. It ensures reliable connectivity through screw-terminal connections and maintains signal clarity with both digital and analog filters. The
Question 4: What are the key features and specifications of the National Instruments NI-9244, including its part number, ADC type, number of channels, sample rate, analog input range, and connection types?
Answer 4: The National Instruments NI-9244 module with part number 783106-01 features high-precision data acquisition capabilities with a 24-bit Delta-Sigma ADC per channel, three single-ended channels that are simultaneously sampled at a rate of 50 kS/s per channel, and an expansive analog input range of 800 Vrms L-L. For protection, it offers 800 Vrms continuous overvoltage protection, can handle 1000 Vrms for 1 second, and is designed to
Question 5: What are the advantages of using the National Instruments NI-9244 module in terms of data acquisition capabilities, connectivity, and protection against electrical stress?
Answer 5: The National Instruments NI-9244, with part number 783106-01, features a 24-bit Delta-Sigma ADC per channel, offers three single-ended, simultaneously sampled AI channels, and provides a sample rate of 50 kS/s per channel. It has an analog input range of 800 Vrms L-L and uses screw-terminal connections for reliable connectivity.