img

PCI-6280

The National Instruments PCI-6280 Multifunction DAQ, part number 779108-01, is designed for PCI slots and offers features like 8 differential analog input channels with an 18-bit ADC resolution, a maximum sampling rate of

In Stock | Ships Today

img

    Description

    The National Instruments PCI-6280 Multifunction DAQ, part number 779108-01, is a versatile data acquisition card for PCI slots that supports SCC and SCXI signal conditioning modules and is equipped with NI-DAQmx driver and configuration utility for ease of use.

    This DAQ device features eight differential analog input channels with a high-resolution ADC of 18 bits and a maximum sampling rate of 625 kS/sec. It is designed to handle a wide input voltage range from +10 V to +0.1 V, with the default range being +10 V, and provides robust overvoltage protection up to +25 V and can withstand a maximum input current of +20 mA during overvoltage conditions.

    An analog trigger with an accuracy of ± 1% and an input impedance of 10 kΩ enhances measurement precision, while the DC-coupled analog channels ensure signal integrity for various applications.

    Additional features include programmable digital I/O channels, which can be configured as inputs or outputs, providing flexibility for interfacing with a range of sensors and actuators.

    Specification Detail
    Manufacturer National Instruments
    Part Number 779108-01
    Product Name PCI-6280 Multifunction DAQ
    Function Multifunction DAQ for PCI Slots
    Signal Conditioning Modules Support SCC and SCXI
    Software Support NI-DAQmx driver and configuration utility
    Analog Input Channels 8 differential channels
    ADC Resolution 18 bits
    Maximum Sampling Rate 625 kS/sec
    Input Voltage Range +10 V to +0.1 V (default range +10 V)
    Overvoltage Protection Up to +25 V
    Maximum Input Current at Overvoltage +20 mA
    Analog Trigger Accuracy +/- 1 %
    Input Impedance of Analog Trigger 10 kΩ
    Coupling of Analog Channels DC-coupled

    Question 1: What is the input impedance of the analog trigger on the National Instruments PCI-6280 Multifunction DAQ, and how does it contribute to measurement precision?
    Answer 1: The input impedance of the analog trigger on the National Instruments PCI-6280 Multifunction DAQ is 10 kΩ, and it contributes to measurement precision by providing a consistent load to the signal source, minimizing the effect of signal source impedance on the measurement accuracy.

    Question 2: What is the maximum overvoltage protection level of the National Instruments PCI-6280 Multifunction DAQ, and how does its analog trigger accuracy contribute to measurement precision?
    Answer 2: The maximum overvoltage protection level of the National Instruments PCI-6280 Multifunction DAQ is +25 V, and its analog trigger accuracy of ±1% contributes to measurement precision by ensuring reliable triggering at the set voltage threshold, leading to consistent and accurate data acquisition.

    Question 3: Considering the specifications detailed about the National Instruments PCI-6280 Multifunction DAQ, can it be used for applications requiring measurement precision beyond a ±1% accuracy threshold?
    Answer 3: The National Instruments PCI-6280 Multifunction DAQ can withstand a maximum input current of +20 mA during overvoltage conditions and offers robust overvoltage protection up to +25 V.

    Question 4: What is the maximum input current that the National Instruments PCI-6280 Multifunction DAQ can withstand during overvoltage conditions, and what is the resulting robustness in terms of overvoltage protection in volts?
    Answer 4: Given the specifications of the National Instruments PCI-6280 Multifunction DAQ, which include an analog trigger with an accuracy of ±1%, the device would not be suitable for applications requiring measurement precision beyond a ±1% accuracy threshold.

    Question 5: What is the accuracy and input impedance of the analog trigger on the National Instruments PCI-6280 Multifunction DAQ, and how does it enhance measurement precision?
    Answer 5: The analog trigger on the National Instruments PCI-6280 Multifunction DAQ has an accuracy of ±1% and an input impedance of 10 kΩ, which enhances measurement precision by providing a stable reference point for capturing data, ensuring consistent and reliable triggering for measurements.