img

NI-9213

The National Instruments NI-9213 is a 16-channel Thermocouple Input Module with a ±2.25 degrees Celsius accuracy and 75 samples per second rate, compatible with CompactDAQ and CompactRIO chassis, offering features like autozero function

In Stock | Ships Today

img

    Description

    The National Instruments NI-9213 Thermocouple Input Module is designed for precise temperature measurements with a maximum accuracy of ±2.25 degrees Celsius, and is compatible with CompactDAQ and CompactRIO chassis. The module features 16 input channels and offers a sample rate of 75 samples per second, ensuring timely and accurate data collection. It is equipped with an autozero function for offset error correction and provides 250 Vrms channel-to-earth continuous isolation for safety and noise reduction. The spring terminal connection type allows for easy and secure wiring.

    With an emphasis on flexibility, the NI-9213 includes noise filtering capabilities for both 50 Hz and 60 Hz signals and offers two timing modes: high-resolution for enhanced precision and high-speed for faster sampling rates. The module’s lightweight design, at just 5.6 ounces, allows for convenient installation and handling.

    Software integration is seamless with compatibility for NI-DAQmx driver software and various programming environments including LabVIEW, LabWindows/CVI, Microsoft Visual C++, and others, while configuration can be easily managed through the Measurement & Automation Explorer (MAX) tool. To maintain its accuracy, a calibration interval of at least once a year is recommended for the NI-9213.

    Specification Detail
    Product National Instruments NI-9213 Thermocouple Input Module
    Part Numbers 780493-01, 780493-02, 785185-01, 785185-02
    Compatibility CompactDAQ and CompactRIO chassis
    Channels 16
    Maximum Accuracy ±2.25 degrees Celsius
    Sample Rate 75 Samples per second
    Autozero Function Yes
    Isolation 250 Vrms Ch-Earth continuous
    Connection Type Spring terminal
    Noise Filtering 50 Hz and 60 Hz
    Weight 5.6 oz
    Timing Modes High-resolution and high-speed
    Software Compatibility NI-DAQmx driver software, LabVIEW, LabWindows/CVI, Microsoft Visual C++, Microsoft Visual Basic, Borland C++, Microsoft .NET
    Configuration Tool Measurement & Automation Explorer (MAX)
    Calibration Interval Recommended at least once a year

    Question 1: What are the key features and benefits of the National Instruments NI-9213 Thermocouple Input Module that enhance its performance in precise temperature measurements and data acquisition?
    Answer 1: The two timing modes available on the National Instruments NI-9213 Thermocouple Input Module are high-resolution, which provides enhanced precision, and high-speed, which allows for faster sampling rates.

    Question 2: What are the key features and compatibility options of the National Instruments NI-9213 Thermocouple Input Module designed for precise temperature measurements?
    Answer 2: The National Instruments NI-9213 Thermocouple Input Module offers benefits such as precise temperature measurements with a maximum accuracy of ±2.25 degrees Celsius, 250 Vrms channel-to-earth continuous isolation to ensure safety and minimize noise interference, and seamless software integration with NI-DAQmx driver software and compatibility with various programming environments like LabVIEW and Microsoft Visual C++, allowing for flexible and easy configuration through the Measurement & Automation Explorer (MAX) tool.

    Question 3: What are the benefits of using the National Instruments NI-9213 Thermocouple Input Module in terms of temperature measurement accuracy, electrical isolation, and software integration?
    Answer 3: The National Instruments NI-9213 Thermocouple Input Module boasts key features including 16 input channels, a sample rate of 75 samples per second, autozero function for offset error correction, 250 Vrms channel-to-earth continuous isolation, spring terminal connections, noise filtering for 50 Hz and 60 Hz signals, high-resolution and high-speed timing modes, and a lightweight design; it is compatible with CompactDAQ and CompactRIO chassis, NI-DAQmx driver software, and programming environments

    Question 4: What are some of the key features and compatibility options of the National Instruments NI-9213 Thermocouple Input Module?
    Answer 4: The National Instruments NI-9213 Thermocouple Input Module boasts key features such as 16 input channels, a sample rate of 75 samples per second, autozero function for offset correction, 250 Vrms channel-to-earth isolation, spring terminal connections, noise filtering for 50/60 Hz signals, and high-resolution and high-speed timing modes; it is compatible with CompactDAQ and CompactRIO chassis, supports NI-DAQmx driver software, and works with programming environments like LabVIEW,

    Question 5: What are the two timing modes available on the National Instruments NI-9213 Thermocouple Input Module that allow users to choose between enhanced precision and faster sampling rates?
    Answer 5: The National Instruments NI-9213 Thermocouple Input Module boasts key features such as 16 input channels, a sample rate of 75 samples per second, autozero function for offset correction, 250 Vrms channel-to-earth isolation for safety and noise reduction, and noise filtering for 50 Hz and 60 Hz signals, all of which enhance its performance in precise temperature measurements and data acquisition. Additionally, its compatibility with CompactDAQ and CompactRIO chassis, various programming environments, and the NI