Description
The National Instruments PCI-6562 Digital Waveform Generator is a versatile tool with part numbers 778992-01, 778992-02, and 778992-03, designed to work with low-voltage differential signaling (LVDS) for enhanced signal integrity and speed.
It boasts a high data rate of up to 400 Mb/s in double data rate (DDR) mode, with options for both single and double data rate modes to accommodate various applications. The device operates at a substantial clock rate of 200 MHz and provides flexible memory options of 2, 16, or 128 Mb/channel, allowing users to choose the best fit for their needs.
Compatible with several software packages, including the NI-HSDIO driver, LabVIEW, LabWindows/CVI, and Measurement Studio, it ensures a broad range of applications can be addressed with ease. The generator features 16 LVDS channels, each with per-channel direction control in single data rate (SDR) mode, enhancing its utility in complex setups.
There are three input and output clock terminals, and users can select between an internal or external clock source, providing flexibility in synchronization. The precise channel-to-channel skew is ±215 picoseconds in generation mode, and ±330 picoseconds in acquisition mode for clock frequencies at or above 25 MHz, ensuring accurate timing for high-performance tasks.
Despite its advanced capabilities, the PCI-6562 is a compact and lightweight device, weighing only 14.5 ounces, making it suitable for various environments without adding significant weight to the system.
Feature | Specification |
---|---|
Product Name | National Instruments PCI-6562 Digital Waveform Generator |
Part Numbers | 778992-01, 778992-02, 778992-03 |
Signal Compatibility | Low-voltage differential signaling (LVDS) |
Data Rate | 400 Mb/s (DDR mode) |
Data Rate Modes | Single and Double Data Rate |
Clock Rate | 200 MHz |
Memory Options | 2, 16, or 128 Mb/channel |
Software Compatibility | NI-HSDIO driver, LabVIEW, LabWindows/CVI, Measurement Studio |
Channels | 16 LVDS channels with per-channel direction control in SDR mode |
Clock Terminals | Three input and output |
Clock Source | Internal or external |
Channel-to-Channel Skew (Generation Mode) | ±215 ps |
Channel-to-Channel Skew (Acquisition Mode) | ±330 ps (for clock frequencies at or above 25 MHz) |
Weight | 14.5 oz |
Question 1: What features make the National Instruments PCI-6562 Digital Waveform Generator suitable for high-performance tasks requiring precise timing and signal integrity?
Answer 1: The National Instruments PCI-6562 Digital Waveform Generator is suitable for high-performance tasks requiring precise timing and signal integrity due to its high data rate of up to 400 Mb/s in DDR mode, operation at a substantial 200 MHz clock rate, flexible memory options of 2, 16, or 128 Mb/channel, compatibility with multiple software packages, 16 LVDS channels with per-channel direction control in SDR mode, three input and output clock terminals with selectable clock sources, and precise
Question 2: What are the benefits and specifications of the National Instruments PCI-6562 Digital Waveform Generator for applications requiring high-speed LVDS communication?
Answer 2: The National Instruments PCI-6562 Digital Waveform Generator is particularly suitable for high-speed, accurate timing, and signal integrity applications due to its high data rate of 400 Mb/s in DDR mode, clock rate of 200 MHz, LVDS compatibility, flexible memory options of up to 128 Mb/channel, precise channel-to-channel skew of ±215 picoseconds in generation mode, and the ability to work with various software packages for broad application support.
Question 3: What are the key features and specifications of the National Instruments PCI-6562 Digital Waveform Generator, including its compatibility with software and performance in generation and acquisition modes?
Answer 3: The National Instruments PCI-6562 Digital Waveform Generator offers benefits such as high-speed LVDS communication with a data rate up to 400 Mb/s in DDR mode, a clock rate of 200 MHz, and flexible memory options of 2, 16, or 128 Mb/channel, ensuring compatibility with a variety of applications. Its specifications include 16 LVDS channels with per-channel direction control, compatibility with several software packages like NI-HSDIO driver and LabVIEW, three input and output
Question 4: What are the key features and applications of the National Instruments PCI-6562 Digital Waveform Generator, and how does its design ensure signal integrity and precise timing in high-performance tasks?
Answer 4: The National Instruments PCI-6562 Digital Waveform Generator is equipped with key features such as low-voltage differential signaling (LVDS) for improved signal integrity and speed, data rates up to 400 Mb/s in DDR mode, a 200 MHz clock rate, and memory options of 2, 16, or 128 Mb/channel. It supports NI-HSDIO driver, LabVIEW, LabWindows/CVI, and Measurement Studio for broad application reach, offers 16 LVDS channels with
Question 5: What features make the National Instruments PCI-6562 Digital Waveform Generator particularly suitable for applications requiring high-speed, accurate timing, and signal integrity?
Answer 5: The National Instruments PCI-6562 Digital Waveform Generator features a high data rate of up to 400 Mb/s in DDR mode, a clock rate of 200 MHz, and flexible memory options of 2, 16, or 128 Mb/channel, compatible with software like NI-HSDIO driver and LabVIEW, and possesses 16 LVDS channels with per-channel direction control. Its design accommodates various applications by offering three I/O clock terminals, selectable internal or external clock sources, and