img

PCI-7344

The National Instruments PCI-7344 Motion Controller Device, part number 778916-04, features advanced capabilities such as 3D contouring and interpolation, a PID loop update rate of up to 62 ms, and supports a 4 MHz

In Stock | Ships Today

img

    Description

    The National Instruments PCI-7344 Motion Controller Device (Part number: 778916-04) excels in complex motion control with features such as 3D contouring, 3D linear and circular interpolation, and an impressive up to 62 ms PID loop update rate. It offers a maximum update rate of 62.5 µs/axis and a versatile trajectory update range from 62.5 to 500 µs/sample, catering to precise motion requirements.

    With a maximum pulse rate of 4 MHz and a maximum pulse width of 120 ns, it ensures high-speed performance over a voltage range of 0 to 5 V. The device is equipped with four 8-bit digital I/O ports, each programmable individually, adding to its flexibility.

    Connectivity is robust, provided by two 68-pin female high-density VHDCI I/O connectors and an RTSI connector, facilitating integration with various systems. The PCI-7344 is compatible with a range of software, including LabVIEW 8.5 or later, Microsoft Visual C++, Microsoft Visual Basic, LabWindows/CVI 8.5 or later, AKD WorkBench Software, and NI-Motion 7.6 or later, making it a versatile solution for developers.

    For hardware compatibility, it requires a computer with a PXI/PCI slot, and for optimal performance, it is recommended to use with a MID-7604 Stepper Motor Drive (Part number: 777936-01), ensuring a complete motion control setup.

    Specification Details
    Product Name National Instruments PCI-7344 Motion Controller Device
    Part Number 778916-04
    Features 3D contouring, 3D linear and circular interpolation, up to 62 ms PID loop update rate
    Maximum Update Rate 62.5 µs/axis
    Trajectory Update Range 62.5 to 500 µs/sample
    Maximum Pulse Rate 4 MHz
    Maximum Pulse Width 120 ns
    Voltage Range 0 to 5 V
    Digital I/O Ports Four 8-bit ports, individually programmable
    Connectors Two 68-pin female high-density VHDCI I/O connectors, RTSI connector
    Software Compatibility LabVIEW 8.5 or later, Microsoft Visual C++, Microsoft Visual Basic, LabWindows/CVI 8.5 or later, AKD WorkBench Software, NI-Motion 7.6 or later
    Hardware Requirements Computer with PXI/PCI slot
    Recommended Motor Drive (Stepper) MID-7604 (Part number: 777936-01)

    Question 1: What are the key features and compatibility requirements of the National Instruments PCI-7344 Motion Controller Device, including its update rates, pulse rates, voltage range, digital I/O ports, connectivity options, software compatibility, and recommended hardware for optimal performance?
    Answer 1: The trajectory update range for the National Instruments PCI-7344 Motion Controller is from 62.5 to 500 µs/sample, and the device is compatible with software platforms such as LabVIEW 8.5 or later, Microsoft Visual C++, Microsoft Visual Basic, LabWindows/CVI 8.5 or later, AKD WorkBench Software, and NI-Motion 7.6 or later.

    Question 2: What is the range of the trajectory update for the National Instruments PCI-7344 Motion Controller and what software platforms are compatible with this device?
    Answer 2: The National Instruments PCI-7344 Motion Controller Device boasts key features such as 3D contouring, 3D linear and circular interpolation, a PID loop update rate of up to 62 ms, a maximum update rate of 62.5 µs/axis, a maximum pulse rate of 4 MHz, a maximum pulse width of 120 ns, and operates over a 0 to 5 V voltage range. It is equipped with four programmable 8-bit digital I/O ports

    Question 3: What are the key features and compatibility requirements of the National Instruments PCI-7344 Motion Controller Device for complex motion control applications?
    Answer 3: The National Instruments PCI-7344 Motion Controller Device boasts key features for complex motion control applications such as 3D contouring, 3D linear and circular interpolation, a PID loop update rate of up to 62 ms, and a maximum pulse rate of 4 MHz, with software compatibility including LabVIEW 8.5 or later and various Microsoft development environments; it requires a PXI/PCI slot for hardware compatibility and is recommended to be used with the MID-7604 Stepper Motor

    Question 4: What are some of the advanced features of the National Instruments PCI-7344 Motion Controller Device that make it suitable for complex motion control applications?
    Answer 4: The National Instruments PCI-7344 Motion Controller Device features 3D contouring, 3D linear and circular interpolation, a PID loop update rate of up to 62 ms, a maximum pulse rate of 4 MHz, and a maximum update rate of 62.5 µs/axis, which together provide the precision and speed required for complex motion control applications.

    Question 5: What are the key features and compatibilities of the National Instruments PCI-7344 Motion Controller Device, including its update rates, pulse specifications, voltage range, I/O ports, software, and recommended hardware for optimal performance?
    Answer 5: The National Instruments PCI-7344 Motion Controller Device features 3D contouring, 3D linear and circular interpolation, up to 62 ms PID loop update rate, a maximum update rate of 62.5 µs/axis, a maximum pulse rate of 4 MHz, a maximum pulse width of 120 ns, and operates over a voltage range of 0 to 5 V. It has four 8-bit digital I/O ports, two 68-pin female high-density VH