img

PCI-7833R

The National Instruments PCI-7833R Digital Reconfigurable I/O Device, part number 779359-01, is a PCI-based device featuring a Virtex-II 3M Gate FPGA, 8 analog I/Os, 96 digital

In Stock | Ships Today

img

    Description

    The National Instruments PCI-7833R Digital Reconfigurable I/O Device, with Part Number 779359-01, is designed for PCI systems and is powered by a Virtex-II 3M Gate FPGA. This device features 8 analog inputs/outputs and a substantial 96 digital I/O lines. With an analog input sampling rate of up to 200 kHz and an analog output update rate reaching 1 MHz, it offers robust performance for various applications.

    It is compatible with the NI-9151 expansion chassis, enhancing its functionality. The FPGA’s impressive specs include 28.672 flip-flops, 96 18×18 multipliers, and 1728 Kbits of embedded block RAM, allowing for customized and complex processing tasks. To operate this device, users need software versions of LabVIEW 7.1 or later, LabVIEW FPGA Module 1.1 or later, NI-RIO 1.3 or later, and the LabVIEW Real-Time Module.

    The device’s output circuitry features an enhanced R-2R DAC with a voltage range of ±10 V, DC output coupling, and is geared towards delivering high-performance signal processing and control applications.

    Specification Details
    Part Number 779359-01
    Product Name National Instruments PCI-7833R Digital Reconfigurable I/O Device
    Form Factor PCI
    FPGA Virtex-II 3M Gate
    Analog Inputs/Outputs 8
    Digital I/O Lines 96
    Analog Input Sampling Rate Up to 200 kHz
    Analog Output Update Rate Up to 1 MHz
    Compatible Expansion Chassis NI-9151
    FPGA Specifications 28.672 flip-flops, 96 18×18 multipliers, 1728 Kbits of embedded block RAM
    Required Software LabVIEW 7.1 or later, LabVIEW FPGA Module 1.1 or later, NI-RIO 1.3 or later, LabVIEW Real-Time Module
    DAC Type Enhanced R-2R
    Voltage Range ±10 V
    Output Coupling DC

    Question 1: What software versions are required to operate the National Instruments PCI-7833R Digital Reconfigurable I/O Device, which is compatible with the NI-9151 expansion chassis?
    Answer 1: To operate the National Instruments PCI-7833R Digital Reconfigurable I/O Device, users need software versions of LabVIEW 7.1 or later, LabVIEW FPGA Module 1.1 or later, NI-RIO 1.3 or later, and the LabVIEW Real-Time Module, and the device is compatible with the NI-9151 expansion chassis.

    Question 2: What is the maximum analog input sampling rate of the National Instruments PCI-7833R Digital Reconfigurable I/O Device?
    Answer 2: The maximum analog input sampling rate of the National Instruments PCI-7833R Digital Reconfigurable I/O Device is 200 kHz.

    Question 3: What are the key features and specifications of the National Instruments PCI-7833R Digital Reconfigurable I/O Device, including its compatibility with software versions and the NI-9151 expansion chassis?
    Answer 3: The National Instruments PCI-7833R Digital Reconfigurable I/O Device features 8 analog inputs/outputs, 96 digital I/O lines, an analog input sampling rate of up to 200 kHz, and an analog output update rate of 1 MHz, powered by a Virtex-II 3M Gate FPGA. It is compatible with the NI-9151 expansion chassis and requires software versions LabVIEW 7.1 or later, LabVIEW FPGA Module 1.1 or later,

    Question 4: What software versions are required to operate the National Instruments PCI-7833R Digital Reconfigurable I/O Device, and what is its compatibility with the NI-9151 expansion chassis?
    Answer 4: The minimum software requirements necessary to operate the National Instruments PCI-7833R Digital Reconfigurable I/O Device are LabVIEW 7.1 or later, LabVIEW FPGA Module 1.1 or later, NI-RIO 1.3 or later, and the LabVIEW Real-Time Module.

    Question 5: What are the minimum software requirements necessary to operate the National Instruments PCI-7833R Digital Reconfigurable I/O Device?
    Answer 5: To operate the National Instruments PCI-7833R Digital Reconfigurable I/O Device, compatible with the NI-9151 expansion chassis, users need software versions of LabVIEW 7.1 or later, LabVIEW FPGA Module 1.1 or later, NI-RIO 1.3 or later, and the LabVIEW Real-Time Module.