img

SCXI-1308

The SCXI-1308 is a 32-channel terminal block with a part number 777687-08, compatible with SCXI-1102/B/C and SCXI-1100 modules, featuring 249 Ω resistors, capable of

In Stock | Ships Today

img

    Description

    The SCXI-1308 is a 32-Channel Terminal Block with a part number of 777687-08 designed for compatibility with SCXI-1102/B/C and SCXI-1100 modules. It features 32 precision resistors each valued at 249 Ω to effectively measure current ranges from 0 to 20 mA and 4 to 20 mA, translating to a voltage measurement range of 0.996 to 4.98 VDC for the latter. The terminal block is engineered to handle channel-to-channel voltages up to 30 Vrms and channel-to-earth voltages of 42.4 Vpeak or 60 VDC.

    Operational efficiency is maintained within an operating temperature range of 0° to 50° C and a storage temperature range from –20° to 70° C. The device also boasts a relative humidity range of 5% to 90% (non-condensing), ensuring reliability under various environmental conditions. Despite its obsolete status announced by National Instruments, the SCXI-1308 remains available for purchase and repair through Apex Waves. Ensuring accurate performance, calibration services are available and are recommended annually or biennially to maintain the device’s precision.

    Feature Specification
    Part Number SCXI-1308
    NI Part Number 777687-08
    Type 32-Channel Terminal Block
    Compatible Modules SCXI-1102/B/C, SCXI-1100
    Resistor Value 249 Ω
    Current Measurement Range 0 to 20 mA, 4 to 20 mA
    Voltage Measurement Range for 4 to 20 mA 0.996 to 4.98 VDC
    Channel-to-Channel Voltage Up to 30 Vrms
    Channel-to-Earth Voltage 42.4 Vpeak or 60 VDC
    Operating Temperature Range 0° to 50° C
    Storage Temperature Range –20° to 70° C
    Relative Humidity Range 5% to 90% (non-condensing)
    Obsolete Status Announced by National Instruments, available from Apex Waves
    Calibration Available; recommended annually or biennially

    Question 1: Considering the SCXI-1308’s specifications and operating conditions, what are the recommended intervals for calibration services to maintain its accuracy?
    Answer 1: The recommended calibration intervals for the SCXI-1308 32-Channel Terminal Block to maintain accurate performance are annually or biennially.

    Question 2: Considering its operational specifications and environmental tolerance, what are the recommended calibration intervals for the SCXI-1308 32-Channel Terminal Block to maintain accurate performance?
    Answer 2: The recommended intervals for calibration services to maintain the accuracy of the SCXI-1308 are annually or biennially.

    Question 3: What are the key specifications and maintenance recommendations for the SCXI-1308, a 32-Channel Terminal Block with a part number of 777687-08, and its compatibility with SCXI modules?
    Answer 3: The SCXI-1308 32-Channel Terminal Block is capable of measuring voltage in the range of 0.996 to 4.98 VDC for the 4 to 20 mA current range and can operate within an ambient temperature range of 0° to 50° C, with a relative humidity range of 5% to 90% (non-condensing).

    Question 4: What are the key specifications and compatibility details of the SCXI-1308 32-Channel Terminal Block, including its operational voltage and temperature ranges, and what services are offered by Apex Waves for this device despite its obsolete status?
    Answer 4: The SCXI-1308, part number 777687-08, is a 32-Channel Terminal Block compatible with SCXI-1102/B/C and SCXI-1100 modules, featuring 32 resistors valued at 249 Ω for current measurements ranging from 0 to 20 mA and 4 to 20 mA, channel-to-channel voltages up to 30 Vrms, and channel-to-earth voltages of 42.4 Vpeak or 60 VDC

    Question 5: What are the specific voltage measurement capabilities and environmental operating conditions for the SCXI-1308 32-Channel Terminal Block?
    Answer 5: The SCXI-1308 is a 32-Channel Terminal Block compatible with SCXI-1102/B/C and SCXI-1100 modules, featuring 32 precision resistors valued at 249 Ω for current measurements ranging from 0 to 20 mA and 4 to 20 mA, translating to a voltage range of 0.996 to 4.98 VDC, with operational channel-to-channel voltages up to 30 Vrms and channel-to-earth voltages up