img

777068-01

The 776910-01 is a legacy E Series DAQ device, model AT-MIO-16XE-50, with 16-bit resolution, supporting up to 20 kS/s streaming rate.

In Stock | Ships Today

img

    Description

    The AT-MIO-16XE-50 is a part of the Legacy DAQ Devices category, with a part number 776910-01. This device falls under the E Series technology, designed to cater to a wide range of data acquisition needs.

    It boasts a maximum stream to disk rate of 20 kS/s, ensuring efficient data handling capabilities. The device is equipped with two 24-bit counter/timers and 8 digital I/O channels, enhancing its versatility in various applications. Additionally, it features two 12-bit analog outputs and supports digital triggering, providing further flexibility in usage.

    The AT-MIO-16XE-50 offers 16 single-ended or 8 differential analog input channels, with a resolution of 16 bits, ensuring precise and accurate data capture. It is compatible with the Traditional NI-DAQ (Legacy) driver software and supports various programming interfaces, including LabVIEW, LabWindows/CVI, and Measurement Studio for VB and VS .NET, making it adaptable to different programming environments.

    Configuration of the device is software-configurable, eliminating the need for manual adjustments through potentiometers, jumpers, or DIP switches. It interfaces with systems through the DAQ-PnP ISA bus interface, and connects via a 68-pin male SCSI-II type I/O connector.

    Regarding power requirements, the AT-MIO-16XE-50 operates on +5 VDC at 0.75 A, with the power at the I/O connector ranging from +4.65 VDC to +5.25 VDC at 1 A. Its physical dimensions are 13.3 x 3.9 inches, making it a compact and efficient solution for various data acquisition tasks. Lastly, it operates within a temperature range of 0 to 55° C, ensuring reliability in diverse working conditions.

    Specification Detail
    Part Number 776910-01
    Category Legacy DAQ Devices
    Model AT-MIO-16XE-50
    Technology E Series
    Maximum Stream to Disk Rate 20 kS/s
    Counter/Timers Two 24-bit
    Digital I/O Channels 8
    Analog Outputs Two 12-bit
    Digital Triggering Yes
    Analog Input Channels 16 single-ended or 8 differential
    Resolution 16 bits
    Driver Software Traditional NI-DAQ (Legacy)
    Programming Interfaces LabVIEW, LabWindows/CVI, Measurement Studio for VB and VS .NET
    Configuration Software-configurable (no potentiometers, jumpers, or DIP switches)
    Bus Interface DAQ-PnP ISA
    I/O Connector 68-pin male SCSI-II type
    Power Requirement +5 VDC at 0.75 A
    Power at I/O Connector +4.65 VDC to +5.25 VDC at 1 A
    Physical Dimensions 13.3 x 3.9 in.
    Operating Temperature Range 0 to 55° C

    Question 1: What is the part number for the AT-MIO-16XE-50?
    Answer 1: 776910-01

    Question 2: How many analog input channels does it have?
    Answer 2: 16 single-ended or 8 differential

    Question 3: What is the maximum streaming rate?
    Answer 3: 20 kS/s

    Question 4: What type of bus interface does it use?
    Answer 4: DAQ-PnP ISA bus interface

    Question 5: What programming environments does it support?
    Answer 5: LabVIEW, LabWindows/CVI, VB, VS .NET