Description
The CompactDAQ Chassis, with a part number of 781157-01, is a sophisticated piece of equipment designed for data acquisition tasks. This chassis, known by its model name cDAQ-9174, is equipped with 4 slots for module integration and leverages a USB 2.0 Hi-Speed Bus interface for fast data transfer.
It supports up to 7 high-performance data streams, including counter/timer output, analog input, counter/timer input, analog output, digital output, and digital input, providing a versatile platform for various data acquisition tasks. The chassis also includes 3 AI timing motors (ai, te0, te1) to ensure precise timing for analog inputs.
Additionally, the cDAQ-9174 is designed to work with start, reference, and pause triggers, enhancing its functionality and making it suitable for a wide range of applications. It is compatible with specific modules like the NI-9401 and NI-9411 for digital input, ensuring a flexible and scalable solution for your data acquisition needs.
Software support is comprehensive, including NI-DAQmx, LabVIEW, LabWindows™/CVI™, C/C++, C#, and Visual Basic .NET, offering a range of programming options to meet various project requirements. The chassis can be configured using the Measurement & Automation Explorer software, simplifying setup and configuration tasks.
Calibration services are available, with NIST accredited calibrations provided through a third party, ensuring accurate and reliable measurements. It is recommended to undergo calibration annually or every two years, depending on your specific requirements and usage patterns, to maintain optimal performance.
| Specification | Detail |
|---|---|
| Part Number | 781157-01 |
| Category | CompactDAQ Chassis |
| Model | cDAQ-9174 |
| Slots | 4 |
| Interface | USB 2.0 Hi-Speed Bus |
| Data Streams | 7 high-performance (counter/timer output, analog input, counter/timer input, analog output, digital output, digital input) |
| AI Timing Motors | 3 (ai, te0, te1) |
| Triggers | Start Trigger, Reference Trigger, Pause Trigger |
| Supported Modules | NI-9401, NI-9411 (for digital input) |
| Software Support | NI-DAQmx, LabVIEW, LabWindows™/CVI™, C/C++, C#, Visual Basic .NET |
| Software Configuration | Measurement & Automation Explorer |
| Calibration | Available, NIST accredited calibrations through a 3rd party |
| Recommended Calibration Period | Annually or every two years |
Question 1: What is the part number for the cDAQ-9174?
Answer 1: 781157-01
Question 2: How many slots does the cDAQ-9174 have?
Answer 2: 4 slots
Question 3: What interface does cDAQ-9174 use?
Answer 3: USB 2.0 Hi-Speed Bus
Question 4: Which modules are compatible with cDAQ-9174?
Answer 4: NI-9401 and NI-9411
Question 5: What software supports the cDAQ-9174?
Answer 5: NI-DAQmx, LabVIEW, LabWindows/CVI, C/C++, C#, VB .NET