Description
The LabVIEW Real-Time/Ethernet Network Controller, model cFP-2020 with part number 777317-2020, is designed for sophisticated control and monitoring tasks. This device is equipped with a single Ethernet port supporting both 10BaseT and 100BaseTX protocols, allowing for versatile connectivity options. Additionally, it features four serial ports: three are RS-232, DTE, and one is RS-485, DTE, facilitating a wide range of communication possibilities with various peripherals.
For storage, the cFP-2020 incorporates CompactFlash as its removable storage medium, complemented by 32 MB of DRAM memory and up to 64 MB of internal nonvolatile storage, ensuring ample space for applications and data. It supports LabVIEW Real-Time Version 8.5.1 and previous versions, offering a robust platform for developing real-time applications.
The device requires a power supply within the range of 11–30 VDC, with the PS-5 (24 V at 120 W) being the recommended power supply unit. Despite its powerful capabilities, the cFP-2020 is lightweight, weighing only 11.5 oz. It operates efficiently within a temperature range of –25 to 60 °C, and can be stored in temperatures ranging from –40 to 85 °C, ensuring reliability in various environmental conditions.
| Specification | Detail |
|---|---|
| Part Number | 777317-2020 |
| Model | cFP-2020 |
| Description | LabVIEW Real-Time/Ethernet Network Controller |
| Ethernet Port | 1 (10BaseT and 100BaseTX) |
| Serial Ports | 4 (Three RS-232, DTE and one RS-485, DTE) |
| Removable Storage | CompactFlash |
| DRAM Memory | 32 MB |
| Internal Nonvolatile Storage | Up to 64 MB |
| Supported LabVIEW Real-Time Version | 8.5.1 and previous versions |
| Power Supply Requirement | 11–30 VDC |
| Recommended Power Supply | PS-5 (24 V at 120 W) |
| Weight | 11.5 oz |
| Operating Temperature Range | –25 to 60 °C |
| Storage Temperature Range | –40 to 85 °C |
Question 1: What is the model and part number of the controller?
Answer 1: Model cFP-2020, part number 777317-2020.
Question 2: What types of serial ports does the cFP-2020 have?
Answer 2: Three RS-232, DTE and one RS-485, DTE.
Question 3: How much DRAM is available in the cFP-2020?
Answer 3: 32 MB of DRAM.
Question 4: What LabVIEW Real-Time version is supported?
Answer 4: Version 8.5.1 and previous.
Question 5: What is the operating temperature range of the cFP-2020?
Answer 5: –25 to 60 °C.