Description
The Compact FieldPoint device identified by the part number 186729B-02, which is also listed as 777318-502, is a specialized module known as the cFP-CTR-502. This module serves as a Counter Input Module, designed to facilitate precise counting operations within a system. It is notable for its capability to handle a leakage current in the OFF state, ensuring that only a minimal amount of current is allowed, thus maintaining efficiency and safety in operations.
When it comes to managing load, the cFP-CTR-502 is engineered to limit the load current to ≤ 1 A per channel, providing a safeguard against excessive power consumption and potential overloading. The module is adept at dealing with a wide range of count values, offering a terminal count range from 0 to 65,535, with the default terminal count value set at 65,535. This broad range allows for flexibility in application and ensures that it can meet various operational demands.
Furthermore, the Gate Input Signal Handling feature of the cFP-CTR-502 is designed for optimal control, enabling counting when the signal is high and disabling it when low. This ensures precise counting operations, critical in applications requiring exact data collection and processing. The module also offers versatility through its Gate Input Channel Options, which include settings for Always Disabled and Always Enabled (default), allowing users to customize the module’s performance based on specific requirements.
In summary, the cFP-CTR-502 Counter Input Module is a highly efficient and flexible solution for precise counting operations, characterized by its minimal leakage current, controlled load current limit, expansive terminal count range, and customizable gate input signal handling. It represents a key component in Compact FieldPoint systems, catering to a wide array of industrial and technical applications.
| Specification | Details |
|---|---|
| Part Number | 186729B-02 (Listed as 777318-502) |
| Category | Compact FieldPoint |
| Model | cFP-CTR-502 |
| Description | Counter Input Module |
| Leakage Current | In OFF state, allows only a small leakage current |
| Load Current Limit | ≤ 1 A per channel |
| Terminal Count Range | 0 to 65,535 |
| Default Terminal Count Value | 65,535 |
| Gate Input Signal Handling | Counting enabled when high, disabled when low |
| Gate Input Channel Options | Always Disabled, Always Enabled (default) |
Question 1: What is the part number for the cFP-CTR-502?
Answer 1: 186729B-02 or 777318-502.
Question 2: What is the load limit of the cFP-CTR-502?
Answer 2: ≤ 1 A per channel.
Question 3: What is the terminal count range of the cFP-CTR-502?
Answer 3: 0 to 65,535.
Question 4: How does the cFP-CTR-502 handle the gate input signal?
Answer 4: Counts when high; disabled when low.
Question 5: What is the default setting for gate input channels?
Answer 5: Always Enabled.