img

191598A-02

The cFP-RLY-425 by National Instruments is a Compact FieldPoint relay output module with 8 SPST channels, supporting up to 250V AC and 125V DC loads.

In Stock | Ships Today

img

    Description

    The Compact FieldPoint cFP-RLY-425, with part number 191598A-02 (777318-425), is a high-quality Relay Output Module designed and manufactured by National Instruments. This module is specifically engineered for switching signals, controlling power circuits, indication lights, and motors, making it an indispensable tool for a wide range of applications. It features 8 non-latching relay channels that are Single Pole Single Throw (SPST), Normally Open.

    One of the notable features of the cFP-RLY-425 is its compatibility with the Hot Plug and Play (HotPnP) option, allowing for easy installation and maintenance without the need for a terminal block. This module is also designed with double insulation to ensure maximum safety and reliability in demanding environments.

    When it comes to electrical specifications, the cFP-RLY-425 can handle an AC input range of up to 250 V and an AC current range between 3-5A. For DC applications, it supports loads up to 125 VDC with an input current range of 0.2-5 A. The module’s switching power capability is impressive, handling up to 750 VA or 90W, making it a versatile choice for various industrial applications.

    Question 1: What is the part number of cFP-RLY-425?
    Answer 1: 191598A-02 (777318-425)

    Question 2: How many relay channels does cFP-RLY-425 have?
    Answer 2: 8 SPST channels

    Question 3: What is the max AC voltage for the cFP-RLY-425?
    Answer 3: Up to 250V AC

    Question 4: Can the cFP-RLY-425 handle DC loads?
    Answer 4: Yes, up to 125V DC

    Question 5: Does the cFP-RLY-425 support Hot Plug and Play?
    Answer 5: Yes

    Specification Detail
    Part Number 191598A-02 (777318-425)
    Category Compact FieldPoint
    Model cFP-RLY-425
    Manufacturer National Instruments
    Function Relay Output Module
    HotPnP Option Yes
    Application Switching signals, controlling power circuits, indication lights, motors
    Terminal Block Not required
    Insulation Double Insulation
    Number of Channels 8 non-latching relay channels
    Relay Type SPST, Normally Open
    AC Input Range 250 V
    AC Current Range 3-5A
    DC Load Support Up to 125 VDC
    DC Input Current Range 0.2-5 A
    Switching Power Up to 750 VA or 90W