Description
The National Instruments cFP-SG-140 Strain/Bridge Input Module is a sophisticated piece of technology designed for the Compact FieldPoint category. With a part number of 187608F-02 (777318-140), this module stands out in its field. It is specifically engineered to facilitate precise data acquisition from eight differential input terminals, making it an invaluable tool for a wide range of applications.
This module boasts an impressive 16-bit Analog-to-Digital Converter (ADC) resolution, ensuring high precision in data conversion. The input terminal impedance is rated at 20 MΩ, which is ideal for a variety of sensor types. To accommodate different sensor requirements, it offers excitation voltages of 2.5 V, 5 V, and 10 V, providing flexibility in application.
To enhance signal integrity, the module is equipped with noise filters at 15 Hz, 60 Hz, and 240 Hz, effectively minimizing unwanted signal disturbances. The channel update rate varies between 1.11 to 0.87 Hz, allowing for adaptable data collection speeds based on the precision and speed requirements of the task at hand.
From a safety perspective, the module is designed to withstand transient voltages up to 2300 Vrms, and it provides a continuous isolation voltage of 250 Vrms. This ensures the protection of both the module and the connected equipment from potential electrical hazards. Additionally, it features two green indicator lights for POWER and READY statuses, and eight red lights for input channels, offering clear and immediate visual feedback about the module’s operational status.
The module is lightweight, weighing only 3.7 oz, and has compact dimensions of 4.3 x 4.2 x 3.6 inches, making it easy to integrate into various setups without requiring excessive space. This combination of features makes the National Instruments cFP-SG-140 an exceptional choice for professionals seeking
| Specification | Detail |
|---|---|
| Part Number | 187608F-02 (777318-140) |
| Category | Compact FieldPoint |
| Model | cFP-SG-140 |
| Description | National Instruments cFP-SG-140 Strain/Bridge Input Module |
| Input Terminals | Eight differential |
| ADC Resolution | 16 bits |
| Input Terminal Impedance | 20 MΩ |
| Excitation Voltages | 2.5 V, 5 V, 10 V |
| Noise Filters | 15 Hz, 60 Hz, 240 Hz |
| Channel Update Rate | 1.11 to 0.87 Hz |
| Transient Voltage | 2300 Vrms |
| Isolation Voltage | 250 Vrms (continuous) |
| Indicator Lights | Two green (POWER and READY), Eight red (input channels) |
| Weight | 3.7 oz |
| Dimensions | 4.3 x 4.2 x 3.6 in |