Description
The 190900E-02L (777318-125) is a part of the Compact FieldPoint category, specifically the model cFP-TC-125. This model is designed for precise temperature measurements and offers a 16 bit Thermocouple Input (TC, mV), capable of handling a 250V Common Mode voltage. It supports a variety of thermocouple types including B, J, E, R, K, S, N, and T, making it versatile for different temperature sensing requirements.
The cFP-TC-125 comes equipped with 8 differential input channels, allowing for multiple measurements to be taken simultaneously. These channels can handle a Common Mode Voltage of ±250 V referenced to earth ground, and a Voltage Input Range from -20 to 80 mV. This wide range ensures accurate and reliable readings across various conditions.
Among its notable features, the device includes built-in linearization and cold-junction compensation to improve accuracy. It also has the capability to sense open thermocouples, and it reports “Out of range” and “Open thermocouple” errors, enhancing the safety and reliability of temperature monitoring processes.
For system integration, the cFP-TC-125 is compatible with cFP-BP-x, cFP-180x backplanes, and cFP-CB-x Connector Block. This compatibility ensures that it can be easily integrated into existing Compact FieldPoint systems, providing a seamless and efficient setup for industrial applications.
| Feature | Description |
|---|---|
| Part Number | 190900E-02L (777318-125) |
| Category | Compact FieldPoint |
| Model | cFP-TC-125 |
| Short Description | cFP-TC-125, 16 bit Thermocouple Input (TC, mV), 250V Common Mode |
| Supported Thermocouple Types | B, J, E, R, K, S, N, T |
| Input Channels | 8 differential |
| Common Mode Voltage | ±250 V referenced to earth ground |
| Voltage Input Range | -20 to 80 mV |
| Features | Built-in linearization, cold-junction compensation, senses open thermocouples, reports “Out of range” and “Open thermocouple” errors |
| Compatible With | cFP-BP-x, cFP-180x backplanes, cFP-CB-x Connector Block |
Question 1: What is the part number of cFP-TC-125?
Answer 1: 190900E-02L (777318-125)
Question 2: How many differential channels does cFP-TC-125 have?
Answer 2: 8 differential input channels
Question 3: What thermocouple types does cFP-TC-125 support?
Answer 3: Supports B, J, E, R, K, S, N, T types
Question 4: What is the common mode voltage of the cFP-TC-125?
Answer 4: ±250 V referenced to earth ground
Question 5: Does the cFP-TC-125 feature built-in linearization?
Answer 5: Yes, it includes built-in linearization