The NI 9250 with BNC – Sound and Vibration Input Module, part number 783827-01, falls under the category of C Series Analog Input modules designed to cater to a variety of sound and vibration analysis applications. This module is equipped with 2 channels that support a voltage range of ±5 V, making it versatile for different types of measurements.
It is compatible with both IEPE and Non-IEPE sensors, such as microphones and accelerometers, and also supports TEDS (Transducer Electronic Data Sheet) for easy sensor setup and configuration. The module features IEPE signal conditioning, allowing for direct connection of IEPE sensors. Users can select between AC or DC coupling through software, providing flexibility for various signal types.
The NI 9250 boasts a maximum sample rate of 102.4 kS/s per channel, ensuring high-resolution data capture. It is equipped with integrated anti-aliasing filters that automatically adjust based on the sample rate, which helps in preserving the integrity of measured signals.
This module is designed to be compatible with various software applications focused on condition monitoring, order tracking, and frequency analysis, enhancing its utility in a wide range of analysis tasks. Connectivity is facilitated through BNC connectors, offering a reliable and easy-to-use interface for connecting sensors.
Furthermore, the module provides a software-selectable IEPE excitation source, enabling or disabling sensor excitation as needed. The excitation current is also software-selectable for AC coupling, offering additional control over sensor operation. The onboard ADC is a 24-bit Delta-Sigma type with analog pre-filtering, ensuring accurate and precise data conversion. Lastly, it features overvoltage protection up to ±30 V (one channel at a time), safeguarding the module against unexpected voltage spikes.
Specification | Detail |
---|---|
Part Number | 783827-01 |
Category | C Series Analog Input |
Model | NI-9250 |
Description | NI 9250 with BNC – Sound and Vibration Input Module |
Channels | 2-Channel, ±5 V Range |
Sensor Compatibility | IEPE and Non-IEPE (microphones and accelerometers), TEDS |
Signal Conditioning | IEPE |
Coupling | Software-selectable AC/DC |
Maximum Sample Rate | 102.4 kS/s/ch |
Anti-Aliasing Filters | Integrated, Adjusts to Sample Rate |
Software Compatibility | Condition monitoring, Order tracking, Frequency analysis |
Connectivity | BNC |
IEPE Excitation Source | Software-selectable Enable/Disable |
Excitation Current | Software-selectable for AC coupling |
ADC Type | 24 bits, Delta-Sigma with analog pre-filtering |
Overvoltage Protection | ±30 V maximum (one channel at a time) |
Question 1: What is the sample rate of NI 9250?
Answer 1: Max 102.4 kS/s per channel.
Question 2: Does NI 9250 support TEDS?
Answer 2: Yes, it supports TEDS for easy sensor setup.
Question 3: Can NI 9250 connect to IEPE sensors?
Answer 3: Yes, it has IEPE signal conditioning for direct connection.
Question 4: What type of connectors does NI 9250 use?
Answer 4: It uses BNC connectors for reliable connectivity.
Question 5: What is the voltage protection of NI 9250?
Answer 5: Overvoltage protection is up to ±30 V (one channel).