144948D-02L

The FD-11614 is a 16-channel National Instruments FieldDAQ device with IP67 protection, designed for outdoor use and test cells.

In Stock | Ships Today

img

    Description

    The 785854-01 is a high-quality FieldDAQ device, notable for its model number FD-11614. This device is meticulously designed for precise temperature measurements, featuring a Mini TC Connector Board. It specifically offers 16 temperature input channels, making it highly suitable for applications requiring multiple temperature readings.

    Manufactured by the renowned National Instruments, this device is supported by the NI-DAQmx driver, ensuring seamless integration and compatibility with Windows operating systems. The robustness of the FD-11614 is evident in its ability to withstand up to 100 g of shock and 10 g of vibration, demonstrating its durability in challenging conditions.

    One of the standout features of this device includes cold junction compensation, which enhances the accuracy of temperature measurements. Additionally, it is equipped with open thermocouple detection to ensure reliability and LED indicators for each channel for easy monitoring. The device boasts an Ingress Protection rating of IP67, highlighting its capability to resist dust and water, making it an ideal choice for outdoor environments and test cells.

    The FD-11614 supports time-sensitive networking, which is crucial for applications requiring synchronized data acquisition across multiple devices. Its operating temperature range from -40 degrees to 85 degrees Celsius further underscores its versatility and reliability in extreme conditions. Whether deployed in outdoor environments or test cells, this FieldDAQ device ensures exceptional performance and reliability.

    Specification Detail
    Part Number 785854-01
    Category FieldDAQ
    Model FD-11614
    Description Temperature Input Device, Mini TC Connector Board, 16CH
    Manufacturer National Instruments
    Driver NI-DAQmx
    Operating System Compatibility Windows
    Number of Channels 16 thermocouple channels
    Shock Range 100 g
    Vibration Capability 10 g
    Features Cold junction compensation, Open thermocouple detection, LED indicator for each channel
    Ingress Protection IP67
    Networking Time-sensitive networking
    Operating Temperature Range -40 degrees to 85 degrees C
    Applications Outdoor environments, Test cells

    Question 1: What is the model number of the FieldDAQ device?
    Answer 1: FD-11614

    Question 2: How many temperature input channels does FD-11614 have?
    Answer 2: 16 channels

    Question 3: What is the IP rating of FD-11614?
    Answer 3: IP67

    Question 4: Does FD-11614 support time-sensitive networking?
    Answer 4: Yes

    Question 5: What is the operating temperature range of FD-11614?
    Answer 5: -40 to 85 degrees Celsius