The PXIe-5644/R VST features 80 MHz bandwidth, operates between 65 MHz to 6 GHz, and supports NI software suites, ensuring versatile signal testing capabilities.

In Stock | Ships Today

img

    Description

    “`html

    The Vector Signal Transceiver (VST) described here, with part numbers 151961B-02L, 782376-01, 150818E-02L, includes models PXIe-5644 and PXIe-5644R. These models offer a versatile solution with a bandwidth of 80 MHz and a frequency range extending from 65 MHz to 6 GHz. They are designed to provide precise performance with an initial adjustment accuracy of ±200 × 109 and exhibit minimal aging, with a factor of ±1 × 10-6 per year.

    The amplitude range of these VSTs goes from the average noise level up to +30 dBm, demonstrating their ability to handle a wide variety of signal strengths. The RF reference level resolution and range are notably precise, with capabilities of ≥60 dB in 1 dB nominal steps. Additionally, the timing resolution is less than 1 Hz, allowing for exceptionally fine adjustments and measurements.

    Connectivity is provided through an SMA (female) connector, which offers a 50 Ω nominal impedance and is AC coupled. The VST supports a comprehensive range of software, including NI-RFmx, NI-RFSA, NI-RFSG, LabVIEW, LabVIEW FPGA Module, and LabVIEW Real-Time Module (optional), making it a flexible option for various applications. For digital I/O, a VHDCI connector is utilized, ensuring compatibility and easy integration into existing systems.

    “`

    Specification Detail
    Part Number 151961B-02L, 782376-01, 150818E-02L
    Category VST (Vector Signal Transceiver)
    Model PXIe-5644 / PXIe-5644R
    Bandwidth 80 MHz
    Frequency Range 65 MHz to 6 GHz
    Initial Adjustment Accuracy ±200 × 109
    Aging Factor ±1 × 10-6 per year
    Amplitude Range Average noise level to +30 dBm
    RF Reference Level Resolution/Range ≥60 dB in 1 dB nominal steps
    Timing Resolution < 1 Hz
    Connector Type SMA (female), 50 Ω nominal impedance, AC coupled
    Software Compatibility NI-RFmx, NI-RFSA, NI-RFSG, LabVIEW, LabVIEW FPGA Module, LabVIEW Real-Time Module (optional)
    Digital I/O Connector VHDCI
    Absolute Maximum Input Range (Digital I/O)Question 1: What is the bandwidth of the PXIe-5644 VST?
    Answer 1: 80 MHz

    Question 2: What is the frequency range of the PXIe-5644?
    Answer 2: 65 MHz to 6 GHz

    Question 3: What type of connector does the PXIe-5644 use?
    Answer 3: SMA (female)

    Question 4: What software suites does the PXIe-5644 support?
    Answer 4: NI-RFmx, NI-RFSA, NI-RFSG, LabVIEW

    Question 5: What is the initial adjustment accuracy of the PXIe-5644?
    Answer 5: ±200 × 10^9