Description
The CompactDAQ Chassis, with part number 782069-01, is a robust and efficient data acquisition system designed for versatile applications. The model cDAQ-9184 features an Ethernet interface, allowing for easy integration into various networking environments.
This chassis is equipped with 4 slots for module installation, providing flexibility in configuring the system according to specific requirements. Each slot is capable of handling an Analog Input FIFO Size of 127 samples, ensuring efficient data buffering during high-speed data acquisition.
The Timing Resolution of the system is an impressive 12.5 ns, coupled with a Timing Accuracy of 50 ppm of the sample rate, which guarantees precise measurements and control. Furthermore, it includes 4 counters/timers with a 32-bit resolution, enhancing its utility for a wide range of timing and counting applications.
The chassis supports an Output Frequency range from 0 MHz to 20 MHz, making it suitable for generating various signals for testing and measurement. It weighs approximately 22.7 oz. and has compact dimensions of 7.01 x 3.47 x 2.53 inches, making it portable and easy to install in constrained spaces.
Designed to operate within a temperature range of -20 °C to 55 °C, this chassis ensures reliability and performance under varying environmental conditions. Calibration services are available to maintain accuracy and performance, with a recommended calibration period of annually or every two years, depending on usage.
| Specification | Detail |
|---|---|
| Part Number | 782069-01 |
| Category | CompactDAQ Chassis |
| Model | cDAQ-9184 |
| Interface | Ethernet |
| Slots | 4 |
| Analog Input FIFO Size | 127 samples per slot |
| Timing Resolution | 12.5 ns |
| Timing Accuracy | 50 ppm of sample rate |
| Counters/Timers | 4 (32-bit resolution) |
| Output Frequency | 0 MHz to 20 MHz |
| Weight | 22.7 oz. |
| Dimensions | 7.01 x 3.47 x 2.53 in. |
| Operating Temperature Range | -20 °C to 55 °C |
| Calibration | Available |
| Recommended Calibration Period | Annually or every two years |
Question 1: What interface does the cDAQ-9184 use?
Answer 1: Ethernet interface.
Question 2: How many slots does cDAQ-9184 have?
Answer 2: 4 slots.
Question 3: What is the Analog Input FIFO Size per slot?
Answer 3: 127 samples.
Question 4: What is the Timing Accuracy of cDAQ-9184?
Answer 4: 50 ppm.
Question 5: What is the recommended calibration period?
Answer 5: Annually or every two years.