Description
The Part Number 782856-01 identifies a specific model within the Category of PXI Source Measure Units, known as the PXIe-4138. This unit is described as the NI PXIe-4138 System SMU, which stands out for its precision and flexibility in electrical testing environments.
The Voltage Range of the NI PXIe-4138 extends from -60 V to 60 V, accommodating a wide array of testing scenarios. Similarly, its Current Range spans from -3 A to 3 A, ensuring versatility in applications requiring varying levels of current.
Featuring multiple Control Modes, including Constant Voltage and Constant Current, the NI PXIe-4138 facilitates precise control over testing parameters. This is further complemented by its Measurement Capability, which supports both Voltage and Current measurements, with options for Local and Remote Sense to ensure accuracy and reliability in results.
The unit is supported by Driver Software known as NI-DCPower, which simplifies integration and operation within test systems. Weighing at 14.8 oz and with Dimensions of 0.8 x 5.1 x 8.5 inches, the PXIe-4138 is compact yet robust, designed to fit into a variety of testing setups without compromising performance.
Operational within an Operating Temperature Range of 0 °C to 55 °C and a Storage Temperature Range of -40 °C to 70 °C, the PXIe-4138 is built to withstand diverse environmental conditions. Its Humidity Range for both Operating and Storage is set between 10% to 90% and 5% to 95% (noncondensing), respectively, highlighting the unit’s resilience. Furthermore, the device is rated for Vibration at 0.3 grms when operating and 2.4 grms when non-operating, ensuring stability and reliability even in physically demanding situations.
| Specification | Detail |
|---|---|
| Part Number | 782856-01 |
| Category | PXI Source Measure Units |
| Model | PXIe-4138 |
| Description | NI PXIe-4138 System SMU |
| Voltage Range | -60 V to 60 V |
| Current Range | -3 A to 3 A |
| Control Modes | Constant Voltage, Constant Current |
| Measurement Capability | Voltage and Current (Local and Remote Sense) |
| Driver Software | NI-DCPower |
| Weight | 14.8 oz |
| Dimensions | 0.8 x 5.1 x 8.5 in |
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | -40 °C to 70 °C |
| Humidity Range (Operating and Storage) | 10% to 90%, 5% to 95% (noncondensing) |
| Vibration (Operating and Non-operating) | 0.3 grms, 2.4 grms
Question 1: What is the voltage range of the PXIe-4138? Question 2: What current range does the PXIe-4138 support? Question 3: Can the PXIe-4138 perform both voltage and current measurements? Question 4: What are the operating temperature limitations of the PXIe-4138? Question 5: What is the part number of the PXIe-4138? |