The product with the Part Number 782878-01 falls under the SC Express category and is modeled as the PXIe-4322. It is a 16-Bit device that features an 8-Channel configuration, providing ample flexibility for various applications. The Signal Conditioning is integrated within the device, ensuring optimal performance and reliability.
One of the key features of this product is its Channel to Channel Isolation, which is critical for minimizing interference between channels. This feature, along with Overvoltage Protection of ±120 volts, ensures the device’s safety and durability in demanding environments. The PXIe-4322 is capable of a Max Update Rate of 250 kS/s per channel, providing high-speed data acquisition capabilities.
Additionally, the device supports both Current Sourcing and Sinking, making it versatile for various applications. It requires a Warm-up Time of 15 minutes before reaching optimal performance levels. The manufacturer recommends a Calibration Period of at least once a year to maintain accuracy and reliability. Speaking of accuracy, the Timing Accuracy is noted at 50 ppm of the sample rate, with a Timing Resolution of 10 nanoseconds.
The Output FIFO Buffer Capacity is substantial, with up to 8,191 samples, supporting efficient data handling. The device offers versatility in waveform generation, supporting both Non-periodic and Periodic AO Waveform Modes. It is compatible with NIDAQmx driver software, easing integration into existing systems.
Despite its robust capabilities, the PXIe-4322 is relatively lightweight at 5.7 oz and compact with dimensions of 6.3 x 3.9 in. It operates within a temperature range of 0 °C to 55 °C
| Specification | Detail |
|---|---|
| Part Number | 782878-01 |
| Category | SC Express |
| Model | PXIe-4322 |
| Bit Depth | 16-Bit |
| Channels | 8-Channel |
| Signal Conditioning | Integrated |
| Channel to Channel Isolation | Yes |
| Overvoltage Protection | ±120 volts |
| Max Update Rate | 250 kS/s per channel |
| Current Sourcing/Sinking | Yes |
| Warm-up Time | 15 minutes |
| Calibration Period | At least once a year |
| Timing Accuracy | 50 ppm of the sample rate |
| Timing Resolution | 10 nanoseconds |
| Output FIFO Buffer Capacity | 8,191 samples |
| AO Waveform Modes | Non-periodic, Periodic |
| Driver Software | NIDAQmx |
| Weight | 5.7 oz |
| Dimensions | 6.3 x 3.9 in |
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | -40 °C to 71 °C |
| Operating Humidity Range | 10% to 90% (non-condensing) |
| Storage Humidity Range | 5% to 95%
Question 1: What is the update rate of the PXIe-4322? Question 2: Does the PXIe-4322 feature overvoltage protection? Question 3: How many channels does PXIe-4322 have? Question 4: What is the warm-up time for PXIe-4322? Question 5: Is channel to channel isolation available on PXIe-4322? |