Description
The product with the part number 157038B-01L (783801-01) falls under the category of PXI Analog Output. This particular model, the PXIe-6739, is equipped with a resolution of 16 Bit, ensuring precise and accurate output. It boasts an impressive 64 analog output channels, making it highly versatile for various applications.
It offers a maximum throughput of 1 MS per second, allowing for efficient data transfer and processing. Additionally, it includes 20 digital I/O lines, further enhancing its utility in complex setups. The analog output voltage range is quite flexible, spanning from -10 V to 10 V, accommodating a wide range of signals.
For software compatibility, it supports NI-DAQmx driver software, ensuring seamless integration and ease of use. It is also compatible with several software packages/ADEs, including LabVIEW, LabWindows/CVI, Measurement Studio, Visual Basic, and ANSI C, offering a broad spectrum of development environments for users to work with.
The device is self-calibrated, with additional calibration possible through NI Measurement & Automation Explorer (MAX). It is recommended to recalibrate the device every two years to maintain optimal performance. As for its physical characteristics, it weighs 6.1 oz. and has dimensions of 6.3 x 6.9 in., making it compact and easy to integrate into various setups.
| Specification | Details |
|---|---|
| Part Number | 157038B-01L (783801-01) |
| Category | PXI Analog Output |
| Model | PXIe-6739 |
| Resolution | 16 Bit |
| Analog Output Channels | 64 |
| Maximum Throughput | 1 MS per second |
| Digital I/O Lines | 20 |
| Analog Output Voltage Range | -10 V to 10 V |
| Driver Software | NI-DAQmx |
| Compatible Software Packages/ADEs | LabVIEW, LabWindows/CVI, Measurement Studio, Visual Basic, ANSI C |
| Calibration | Self-calibrated; Calibrated by NI Measurement & Automation Explorer (MAX); Recommended every two years |
| Weight | 6.1 oz. |
| Dimensions | 6.3 x 6.9 in. |
Question 1: What is the resolution of the PXIe-6739?
Answer 1: 16 Bit
Question 2: How many analog output channels does the PXIe-6739 have?
Answer 2: 64 channels
Question 3: What is the maximum throughput of the PXIe-6739?
Answer 3: 1 MS/s
Question 4: Which programming environments is the PXIe-6739 compatible with?
Answer 4: LabVIEW, LabWindows/CVI, Measurement Studio, Visual Basic, ANSI C
Question 5: What is the recommended recalibration frequency for the PXIe-6739?
Answer 5: Every two years