Description
The 157038D-01L is a high-quality PXI Analog Output module, specifically the model PXIe-6739. This module is equipped with 64 Analog Outputs, making it an ideal choice for extensive data acquisition and control systems. The module boasts a maximum sample rate of 400 kS/s/ch, ensuring rapid data processing and response times.
With a 16-bit resolution, the PXIe-6739 provides precise output, catering to applications requiring high accuracy. The analog output voltage range is quite flexible, spanning from -10 V to 10 V, which allows for a wide range of signal generation capabilities. Additionally, the module includes 20 digital I/O lines, further enhancing its versatility in integrating with various digital systems.
Software compatibility is extensive, encompassing LabVIEW, LabWindows/CVI, Measurement Studio, Visual Basic, and ANSI C. This ensures that the module can easily integrate into existing software environments, making it a seamless addition to any project. The required driver software is NI-DAQmx, which is known for its reliability and ease of use.
The PXIe-6739 is self-calibrated, with a recommended recalibration period of every two years, which simplifies maintenance and ensures ongoing accuracy and reliability. Its physical characteristics include a weight of 6.1 oz. and dimensions of 6.3 x 6.9 in., making it a compact yet powerful component within any PXI system.
| Specification | Detail |
|---|---|
| Part Number | 157038D-01L |
| Category | PXI Analog Output |
| Model | PXIe-6739 |
| Channels | 64 Analog Outputs |
| Maximum Sample Rate | 400 kS/s/ch |
| Resolution | 16-bit |
| Analog Output Voltage Range | -10 V to 10 V |
| Digital I/O Lines | 20 |
| Software Compatibility | LabVIEW, LabWindows/CVI, Measurement Studio, Visual Basic, ANSI C |
| Driver Software | NI-DAQmx |
| Calibration | Self-calibrated; Recommended every two years |
| Weight | 6.1 oz. |
| Dimensions | 6.3 x 6.9 in. |
Question 1: What is the resolution of the PXIe-6739?
Answer 1: 16-bit
Question 2: How many analog outputs does the PXIe-6739 have?
Answer 2: 64
Question 3: What is the maximum sample rate of the PXIe-6739?
Answer 3: 400 kS/s/ch
Question 4: What voltage range does the PXIe-6739 support?
Answer 4: -10 to 10 V
Question 5: What is the recommended recalibration period for PXIe-6739?
Answer 5: Every two years