Description
The product described by the technical specifications table is a C Series Temperature Input Module, designed to provide precise temperature measurements and suitable for a wide range of applications. This module supports multiple Part Numbers including 783863-01, 783863-02, 785186-01, and 783664-01, each tailored to meet specific user needs.
It features 8 channels, allowing it to monitor temperatures from multiple sources simultaneously. The module boasts a high Sample Rate of 400 samples per second, ensuring that temperature data is updated frequently and accurately. With a Resolution of 24 bits, it can detect even the smallest changes in temperature, providing high precision in measurements.
Isolation between channels and earth ground varies depending on the part number, with 60 Vrms isolation for part numbers 783863-01 and 783863-02, and higher isolation of 250 Vrms for part number 785186-01. This feature enhances safety and reduces the risk of electrical interference affecting measurements.
The module comes in two Connector Types: D-Sub for part numbers 783863-01 and 783863-02, and Spring Terminal for part number 785186-01, offering flexibility in connecting to different types of sensors and systems. Its Measurement Range spans from 0 to 400 ohms, accommodating a wide range of temperature sensors.
Operating modes include both High sample rate and High resolution options, allowing users to prioritize between faster data updates or more detailed temperature readings. The Conversion Time varies with mode; in High Resolution Mode, it takes 200 ms per channel or 1600 ms for all channels, while in High-Speed Mode, it significantly reduces to 2.5 ms per channel or 20 ms for all channels, facilitating rapid data collection when needed.
The module is lightweight, with the Spring Terminal version weighing 5.7 oz and the D-Sub version weighing 5.04 oz
Question 2: How many channels does the NI-9216 have? Question 3: What is the resolution of the NI-9216? Question 4: What’s the isolation for part number 785186-01? Question 5: What are the operating temperatures for the NI-9216?
Specification
Details
Part Numbers
783863-01, 783863-02, 785186-01, 783664-01
Category
C Series Temperature Input Module
Channels
8
Sample Rate
400 samples per second
Resolution
24 bits
Isolation (Ch-Earth Ground)
60 Vrms (783863-01, 783863-02), 250 Vrms (785186-01)
Connector Type
D-Sub (783863-01, 783863-02), Spring Terminal (785186-01)
Measurement Range
0 to 400 ohms
Operating Modes
High sample rate, High resolution
Conversion Time (High Resolution Mode)
200 ms per channel, 1600 ms for all channels
Conversion Time (High-Speed Mode)
2.5 ms per channel, 20 ms for all channels
Weight
5.7 oz (Spring Terminal), 5.04 oz (D-Sub)
Operating Temperature Range
-40 °C to 70 °C
Storage Temperature Range