Description
The product with part numbers 784305-01, 784306-01, and 140001B-03L falls under the category of NI USRP and is identified by the model CDA-2990. This product is described as a CCA, OctoClock 8 Channel Clock Distribution System, designed to distribute clock signals efficiently across multiple channels.
It features 8 channels with AC input/output coupling, making it suitable for a wide range of applications. The system is capable of accepting PPS and 10 MHz inputs, ensuring compatibility with standard frequency sources.
Regarding outputs, this device provides eight PPS SMA and eight 10 MHz outputs, allowing for extensive connectivity options. The reference clock input power range is quite flexible, ranging from 0 dBm to 20 dBm, accommodating various signal strengths.
The clock output frequency is set at 10 MHz, with the clock output power reaching up to 10 dBm. For precise timekeeping and synchronization, the PPS output voltage can go up to 5 V, providing a clear and strong signal.
Powering this system is straightforward, requiring a 6 VDC to 15 VDC power supply, and it operates efficiently with a maximum input power of 6 W. This specification ensures that the device can be easily integrated into existing setups without the need for substantial power adjustments.
| Specification | Details |
|---|---|
| Part Number | 784305-01, 784306-01, 140001B-03L |
| Category | NI USRP |
| Model | CDA-2990 |
| Description | CCA, OctoClock 8 Channel Clock Distribution System |
| Channels | 8 |
| Input/Output Coupling | AC |
| Inputs | PPS and 10 MHz |
| Outputs | Eight PPS SMA and eight 10 MHz |
| Reference Clock Input Power Range | 0 dBm to 20 dBm |
| Clock Output Frequency | 10 MHz |
| Clock Output Power | Up to 10 dBm |
| PPS Output Voltage | Up to 5 V |
| Power Supply | 6 VDC to 15 VDC |
| Maximum Input Power | 6 W |
Question 1: What is the model number for the NI USRP OctoClock?
Answer 1: CDA-2990
Question 2: How many channels does the CDA-2990 have?
Answer 2: 8 channels
Question 3: What inputs does the CDA-2990 accept?
Answer 3: PPS and 10 MHz
Question 4: What is the power range for the reference clock input?
Answer 4: 0 dBm to 20 dBm
Question 5: What is the required power supply for the CDA-2990?
Answer 5: 6 VDC to 15 VDC