img

158031D-120L

The PXIe-5413 is a versatile signal generator with a frequency range up to 20 MHz and supports arbitrary waveform sizes from 2 to 64 million samples.

In Stock | Ships Today

img

    Description

    The PXIe-5413 is a model known for its precision and versatility in generating waveforms. It comes with two part numbers, 784181-01 and 785114-01, indicating different packaging or configuration options available to users. This device boasts an impressive frequency range of up to 20 MHz, ensuring it can handle a wide variety of applications.

    One of the standout features of the PXIe-5413 is its step response rise time of 14.8 ns, allowing for quick changes in signal generation without sacrificing accuracy. Additionally, it supports an arbitrary waveform size ranging from 2 samples to a staggering 64,000,000 samples, providing unparalleled flexibility in waveform generation.

    Users can benefit from a user sample rate of 5.6 µS/s to 200 MS/s when the digital filter is enabled, and an even wider range of 3.125 MS/s to 200 MS/s when the digital filter is disabled. This feature ensures that the PXIe-5413 can be finely tuned for both high-precision and high-speed applications.

    The device’s frequency step size is precisely 2.84 µHz, allowing for very fine adjustments to the output frequency. With 8,192 waveform points, users have extensive control over the shape and structure of the generated waveforms.

    For synchronization and timing purposes, the PXIe-5413 utilizes a reference clock frequency of 100 MHz (±25 ppm) and boasts a sample clock rate of 800 MHz. This high sample clock rate is crucial for achieving the fast and accurate waveform generation the device is capable of.

    The PFI I/O frequency range of 0 MHz to 25 MHz ensures compatibility with a wide range of external devices and signals. Additionally, the maximum input voltage of +5 V allows the PXIe-5413 to handle robust signals without risk of damage.

    In terms of durability, the PXIe-5413 is designed to withstand significant physical stress, with an operating shock resistance of 30 g peak, half-sine, 11 ms pulse, and random vibration resistance of 0.3 grms (operating) and 2.4 grms (non-operating) across a frequency range of 5 Hz to 500 Hz. These specifications ensure that the PXIe-5413 remains reliable and accurate, even in

    Specification Detail
    Model PXIe-5413
    Part Numbers 784181-01, 785114-01
    Frequency Range Up to 20 MHz
    Step Response Rise Time 14.8 ns
    Arbitrary Waveform Size 2 samples to 64,000,000 samples
    User Sample Rate (With Digital Filter Enabled) 5.6 µS/s to 200 MS/s
    User Sample Rate (Digital Filter Disabled) 3.125 MS/s to 200 MS/s
    Frequency Step Size 2.84 µHz
    Waveform Points 8,192
    Reference Clock Frequency 100 MHz (±25 ppm)
    Sample Clock Rate 800 MHz
    PFI I/O Frequency Range 0 MHz to 25 MHz
    Maximum Input Voltage +5 V
    Operating Shock 30 g peak, half-sine, 11 ms pulse
    Random Vibration (Operating) 5 Hz to 500 Hz, 0.3 grms
    Random Vibration (Non-Operating) 5 Hz to 500 Hz, 2.4 grms

    Question 1: What frequency range does the PXIe-5413 support?
    Answer 1: Up to 20 MHz.

    Question 2: What is the step response rise time of the PXIe-5413?
    Answer 2: 14.8 ns.

    Question 3: How many samples can the PXIe-5413’s waveform range?
    Answer 3: From 2 to 64 million samples.

    Question 4: What is the sample clock rate of the PXIe-5413?
    Answer 4: 800 MHz.

    Question 5: What is the maximum input voltage the PXIe-5413 can handle?
    Answer 5: +5 V.