Description
The PXIe-5413 is a model with part numbers 784181-01 and 785114-01. This device boasts a frequency range that goes up to 20 MHz, ensuring broad application coverage. Its step response rise time is impressively quick at 14.8 ns, allowing for efficient signal processing.
When it comes to waveform generation, the PXIe-5413 excels with an arbitrary waveform size that ranges from 2 samples to 64,000,000 samples. Users have a wide range of sample rates to choose from, with the device supporting 5.6 µS/s to 200 MS/s when the digital filter is enabled and 3.125 MS/s to 200 MS/s when it is disabled. The frequency step size is as precise as 2.84 µHz, and it can handle up to 8,192 waveform points.
The device operates with a reference clock frequency of 100 MHz (±25 ppm) and a sample clock rate of 800 MHz. For added versatility, the PFI I/O frequency range spans from 0 MHz to 25 MHz. The maximum input voltage capacity is +5 V, making the system robust for various operational demands.
In terms of durability, the PXIe-5413 is designed to withstand significant stress. It can handle an operating shock of 30 g peak, half-sine, 11 ms pulse. Moreover, the device is capable of enduring random vibrations while operating within a range of 5 Hz to 500 Hz at 0.3 grms and can withstand non-operating random vibrations in the same frequency range at a higher intensity of 2.4 grms.
| Specification | Detail |
|---|---|
| Model | PXIe-5413 |
| Part Numbers | 784181-01, 785114-01 |
| Frequency Range | Up to 20 MHz |
| Step Response Rise Time | 14.8 ns |
| Arbitrary Waveform Size | 2 samples to 64,000,000 samples |
| User Sample Rate (Digital Filter Enabled) | 5.6 µS/s to 200 MS/s |
| User Sample Rate (Digital Filter Disabled) | 3.125 MS/s to 200 MS/s |
| Frequency Step Size | 2.84 µHz |
| Waveform Points | 8,192 |
| Reference Clock Frequency | 100 MHz (±25 ppm) |
| Sample Clock Rate | 800 MHz |
| PFI I/O Frequency Range | 0 MHz to 25 MHz |
| Maximum Input Voltage | +5 V |
| Operating Shock | 30 g peak, half-sine, 11 ms pulse |
| Random Vibration (Operating) | 5 Hz to 500 Hz, 0.3 grms |
| Random Vibration (Non-operating) | 5 Hz to 500 Hz, 2.4 grms |
Question 1: What is the max frequency range of the PXIe-5413?
Answer 1: Up to 20 MHz.
Question 2: What sample clock rate does the PXIe-5413 support?
Answer 2: 800 MHz.
Question 3: What is the max arbitrary waveform size for PXIe-5413?
Answer 3: Up to 64,000,000 samples.
Question 4: What’s the reference clock frequency of PXIe-5413?
Answer 4: 100 MHz (±25 ppm).
Question 5: How much input voltage can the PXIe-5413 handle?
Answer 5: Up to +5 V.