Description
The Part Number 783920-01 refers to a C Series Analog Input model named NI-9246. This model is designed to handle a Sample Rate of 50 kS/s/ch across its 3 channels. It boasts a high-resolution data acquisition capability with a 24-Bit resolution. The Input Range for each channel is designed to accommodate ±30 A peak, making it suitable for a wide variety of applications.
This model supports Current Transformer (CT) Ratings of 1 and 5 Ampere, providing flexibility in measurement options. For connecting cables, it features Ring Lug Connectors that can accommodate up to 10 AWG cables, ensuring a secure and reliable connection.
It also emphasizes safety and reliability with a Channel-to-Channel Isolation of 480 Vrms and Channel-to-Earth Isolation rated at 300 Vrms CAT III. This ensures that each channel operates independently without interference, and the device as a whole can safely be used in high-voltage environments.
When it comes to AC Measurement Capability, the NI-9246 can measure up to 22 Arms, with an Input Coupling feature designed for AC signals. The Input Noise level is exceptionally low at 0.25 mArms, ensuring accurate measurements. The device is also equipped with a High voltage backshell for added safety and durability.
Among the Included Accessories, there are 6 ring lugs provided for immediate setup. Each channel of the NI-9246 utilizes a Delta-Sigma ADC, offering precise and reliable data conversion. Moreover, the device is built to withstand Overcurrent Protection conditions of 50 Arms continuous, 100 Arms for 10 seconds, and 1250 Arms for 1 cycle, safeguarding the equipment
| Specification | Detail |
|---|---|
| Part Number | 783920-01 |
| Category | C Series Analog Input |
| Model | NI-9246 |
| Sample Rate | 50 kS/s/ch |
| Number of Channels | 3 |
| Resolution | 24-Bit |
| Input Range | ±30 A peak |
| Current Transformer (CT) Ratings | 1 and 5 Ampere |
| Connectivity | Ring Lug Connectors for up to 10 AWG cables |
| Channel-to-Channel Isolation | 480 Vrms |
| Channel-to-Earth Isolation | 300 Vrms CAT III |
| AC Measurement Capability | Up to 22 Arms |
| Input Coupling | AC |
| Input Noise | 0.25 mArms |
| Backshell | High voltage backshell |
| Included Accessories | 6 ring lugs |
| ADC Type | Delta-Sigma ADC on each channel |
| Overcurrent Protection | 50 Arms continuous, 100 Arms for 10 seconds, 1250 Arms for 1 cycle |
Question 1: What is the sample rate of the NI-9246?
Answer 1: 50 kS/s/ch
Question 2: How many channels does the NI-9246 have?
Answer 2: 3 channels
Question 3: What is the input range of the NI-9246?
Answer 3: ±30 A peak
Question 4: What ADC type does the NI-9246 use?
Answer 4: Delta-Sigma ADC
Question 5: What is the channel-to-earth isolation rating for NI-9246?
Answer 5: 300 Vrms CAT III