Description
“`html
The AT-MIO-16F-5 is a legacy Data Acquisition (DAQ) device with the part number 180985-01, manufactured by National Instruments. This model falls under the category of Legacy DAQ Devices and is designed to be compatible with IBM PC AT, compatibles, and EISA PCs.
This device features 16 single-ended channels that can be configured as 8 differential channels to suit various measurement needs. Additionally, it can be expanded with the AMUX-64T to support up to 64 single-ended or 32 differential inputs, and even further to 256 single-ended channels with 4 cascaded AMUX-64Ts.
The Analog to Digital Converter (ADC) of the AT-MIO-16F-5 boasts a 256-word buffer and can process approximately 200 ksamples per second. Its variable gain setting ranges from 0.5 to 100, providing flexibility for various signal strengths.
Moreover, it features 12-bit, double-buffered Digital to Analog Converters (DACs) with both unipolar and bipolar outputs, enhancing its versatility. The device also supports auto-calibration to ensure accuracy and reliability over time.
For interfacing, the AT-MIO-16F-5 is equipped with 8 digital I/O lines, 4 triggers for event management, and a RTSI bus interface for expanded connectivity.
Its applications are vast, including but not limited to process control, level monitoring, electronic testing, transient analysis, and data acquisition tasks, making it a versatile choice for various fields.
“`
| Specification | Description |
|---|---|
| Part Number | 180985-01 |
| Category | Legacy DAQ Devices |
| Model | AT-MIO-16F-5 |
| Manufacturer | National Instruments |
| Compatibility | IBM PC AT, compatibles, EISA PCs |
| Channels | 16 single-ended (configurable as 8 differential) |
| Expansion with AMUX-64T | Up to 64 single-ended or 32 differential inputs, 256 single-ended channels with 4 cascaded AMUX-64T |
| Analog to Digital Converter (ADC) | 256-word buffer, ~200 ksamples/sec |
| Variable Gain Setting | 0.5 to 100 |
| Digital to Analog Converters | 12-bit, double-buffered, unipolar and bipolar output |
| Auto-Calibration | Yes |
| Digital I/O Lines | 8 |
| Triggers | 4 |
| RTSI Bus Interface | Yes |
| Applications | Process control, level monitoring, electronic testing, transient analysis, data
Question 1: What is the part number for the AT-MIO-16F-5 DAQ device? Question 2: How many single-ended channels does the AT-MIO-16F-5 support initially? Question 3: Can the AT-MIO-16F-5 be expanded to support more channels? Question 4: What is the max sampling rate of the AT-MIO-16F-5’s ADC? Question 5: Does the AT-MIO-16F-5 feature auto-calibration? |