The National Instruments GPIB-SCSI-A controller supports up to 14 GPIB and 7 SCSI devices with transfer rates up to 1.0 Mbytes/s.

In Stock | Ships Today

img

    Description

    The GPIB-SCSI-A model, manufactured by National Instruments, is a specialized GPIB SCSI Controller designed for seamless integration and control of multiple devices. This controller is capable of managing up to 14 GPIB instruments and up to 7 SCSI devices, allowing for a versatile and efficient setup in various technical environments.

    It supports dual control modes, specifically SCSI(S) and GPIB(G), to accommodate different types of devices and configurations. Moreover, it includes comprehensive IEEE-488.2 functions such as Talker, Listener, and Controller, ensuring compatibility and control across a broad range of instruments.

    One of the key features of the GPIB-SCSI-A is its software selectable SCSI addresses, which provide flexibility in device management and setup. The controller boasts impressive data transfer rates, with a maximum transfer rate of 1.0 Mbytes/s for SCSI/GPIB read into buffer operations, 800 kbytes/s for SCSI read and GPIB read from buffer operations, and 600 kbytes/s for SCSI read/GPIB write with no buffering.

    Designed to operate within a broad input voltage range of 120-240 VAC, it accommodates various power supplies and ensures reliability in different working conditions. Additionally, the inclusion of a 256 kbytes RAM buffer enhances its performance by facilitating efficient data processing and storage.

    The GPIB-SCSI-A controller is available under several part numbers, including 776569-01, 776569-02, 776569-03, 776569-04, 776569-05, and 776569-06, offering a range of options to meet specific requirements and configurations.

    Question 1: What is the maximum number of GPIB devices supported?
    Answer 1: Up to 14 GPIB instruments.

    Question 2: How many SCSI devices can the GPIB-SCSI-A control?
    Answer 2: It can control up to 7 SCSI devices.

    Question 3: What is the maximum data transfer rate of the GPIB-SCSI-A?
    Answer 3: 1.0 Mbytes/s for SCSI/GPIB read into buffer.

    Question 4: Can the SCSI address be selected through software?
    Answer 4: Yes, it has software selectable SCSI addresses.

    Question 5: What input voltage range does the GPIB-SCSI-A operate in?
    Answer 5: 120-240 VAC.

    Specification Detail
    Part Numbers 776569-01, 776569-02, 776569-03, 776569-04, 776569-05, 776569-06
    Manufacturer National Instruments
    Model GPIB-SCSI-A
    Category GPIB SCSI Controller
    GPIB Control Capability Up to 14 GPIB instruments
    SCSI Control Capability Up to 7 SCSI devices
    Control Modes SCSI(S) and GPIB(G)
    IEEE-488.2 Functions Talker, Listener, Controller
    SCSI Addresses Software Selectable
    Maximum Transfer Rate (SCSI/GPIB Read into Buffer) 1.0 Mbytes/s
    Maximum Transfer Rate (SCSI Read and GPIB Read from Buffer) 800 kbytes/s
    Maximum Transfer Rate (SCSI Read/GPIB Write No Buffering) 600 kbytes/s
    Input Voltage Range 120-240 VAC