img

181445J-01

The SCXI-1000 is a chassis for SCXI modules with 7 power options, supports up to 8 chassis per system, and operates between 0 to 50 °C.

In Stock | Ships Today

img

    Description

    The SCXI-1000 chassis is designed for SCXI modules and supports a wide range of part numbers including 776570-01, 776570-02, 776570-03, 776570-04, 776570-05, 776570-06, 776570-07, 778570-01, 778570-04, 776570-09, and 776570-10. It allows for a maximum of 8 chassis per system, providing flexibility in system expansion.

    This chassis offers 7 different power options to accommodate various line voltages including 100, 120, 220, and 240 VAC, ensuring compatibility with global power standards. Users can operate the SCXI-1000 in either multiplexed or parallel operational modes, depending on the application’s requirements. It also supports one of 32 distinct addresses for versatile address configuration.

    With a weight of 10 oz and dimensions of 9.8 x 7.7 x 7.0 inches, this chassis is compact yet robust. It has a power dissipation of 7 W per slot, optimizing energy consumption across modules. The SCXI-1000 operates effectively within a temperature range of 0 to 50 °C and can be stored in temperatures ranging from –20 to 70 °C.

    It is important to note that the SCXI-1000 has been announced as obsolete by National Instruments. This status indicates that the product is no longer in active production or development, and support may be limited.

    Specification Detail
    Model SCXI-1000
    Part Numbers 776570-01, 776570-02, 776570-03, 776570-04, 776570-05, 776570-06, 776570-07, 778570-01, 778570-04, 776570-09, 776570-10
    Type Chassis for SCXI modules
    Maximum Number of Chassis per System 8
    Power Options 7 different power options
    Line Voltages 100, 120, 220, 240 VAC
    Operational Modes Multiplexed, Parallel
    Address Configuration One of 32 distinct addresses
    Weight 10 oz
    Dimensions 9.8 x 7.7 x 7.0 in
    Power Dissipation 7 W per slot
    Operating Temperature Range 0 to 50 °C
    Storage Temperature Range –20 to 70 °C
    Obsolete Status Announced by National

    Question 1: What is the maximum number of SCXI-1000 chassis per system?
    Answer 1: Up to 8 chassis can be supported per system.

    Question 2: What power voltages does the SCXI-1000 support?
    Answer 2: 100, 120, 220, and 240 VAC.

    Question 3: Can the SCXI-1000 operate in multiplexed mode?
    Answer 3: Yes, it supports multiplexed and parallel modes.

    Question 4: What is the operating temperature range of the SCXI-1000?
    Answer 4: 0 to 50 °C.

    Question 5: Is the SCXI-1000 still in active production?
    Answer 5: No, it has been announced as obsolete.