The SCXI-1302 is a fully shielded, 50-screw terminal block compatible with the SCXI-1180 panel and supports rack or DIN-rail mounting.

In Stock | Ships Today

img

    Description

    HTML Description:

    The SCXI-1302 Feedthrough Terminal Block, with part number 777687-02 (originally 181730B-01), falls under the SCXI & Legacy category. This model, SCXI-1302, is designed to facilitate seamless connectivity and integration within your test and measurement setups.

    The terminal block features a 50-screw Front-Mount Terminal Block, offering robust connections for a wide array of signal types. It is specifically compatible with the SCXI-1180 Feedthrough Panel, ensuring a secure and reliable connection for your systems. For installation, the terminal block provides flexible rack-mount and DIN-rail-mount options, catering to various setup requirements and preferences.

    To enhance its utility, the terminal block comes with strain-relief clamps, aimed at improving the longevity and reliability of wire connections. Moreover, its fully shielded casing ensures superior protection against external noise, enhancing signal integrity for critical applications.

    Regarding technical specifications, it supports a field wire gauge of 26-16 AWG maximum, and features DC coupling with a corner frequency of 0.16 Hz 1-pole RC. It also boasts DC Rejection capabilities of ±50 VDC, making it suitable for various signal conditioning tasks.

    The terminal block is compatible with NIDAQmx driver software, and can be programmed using multiple environments including LabVIEW, LabWindows/CVI, and ComponentWorks. Additionally, it supports configuration via the Measurement & Automation Explorer (MAX), further simplifying setup and integration into your systems.

    Specification Detail
    Part Number 777687-02 (Originally 181730B-01)
    Category SCXI & Legacy
    Model SCXI-1302
    Description SCXI-1302 Feedthrough Terminal Block
    Terminal Type 50-screw Front-Mount Terminal Block
    Compatibility SCXI-1180 Feedthrough Panel
    Mounting Options Rack-mount and DIN-rail-mount
    Accessories Strain-relief clamps
    Shielding Fully shielded casing
    Field Wire Gauge 26-16 AWG maximum
    Coupling DC
    Corner Frequency 0.16 Hz 1-pole RC
    DC Rejection ±50 VDC
    Driver Software NIDAQmx
    Programming Environments LabVIEW, LabWindows/CVI, ComponentWorks
    Configuration Tool Measurement &

    Question 1: What is the part number for SCXI-1302?
    Answer 1: Originally 181730B-01, now 777687-02.

    Question 2: Can SCXI-1302 be mounted on a DIN rail?
    Answer 2: Yes, it supports rack and DIN-rail mounting.

    Question 3: What is supported wire gauge for SCXI-1302?
    Answer 3: 26-16 AWG maximum.

    Question 4: Does SCXI-1302 feature strain-relief clamps?
    Answer 4: Yes, to improve connection longevity.

    Question 5: Is SCXI-1302 compatible with NIDAQmx software?
    Answer 5: Yes, and with LabVIEW, LabWindows/CVI.