The Part Number 182415F-01 refers to a product in the SCXI & Legacy category, specifically the model SCXI-1200. This model is a National Instruments SCXI-1200 Data Acquisition and Control Module, designed for versatile and efficient data acquisition and control tasks.
This module boasts a 12-bit resolution, allowing for precise data measurement and analysis. It supports 8 single-ended or 4 differential analog input channels, giving users flexibility in connecting various sensors and inputs. The input modes available are Referenced single-ended (RSE), Non-referenced single-ended (NRSE), and Differential (DIFF), accommodating a wide range of signal types.
In addition to its input capabilities, the SCXI-1200 provides 2 single-ended analog output channels, enabling direct control of external devices based on data analysis. The module’s analog input range is versatile, offering both 0 V to 10 V (unipolar) and -5 V to +5 V (bipolar) options to suit different application requirements.
The device also includes 32 digital I/O channels, which are TTL compatible, further expanding its utility in complex systems requiring digital communication or signaling. To protect against potential damage, it features overload protection of ±42 V when powered on and ±15 V when powered off.
Before calibration, the offset error can be up to ±50 mV max, which can be reduced to ±0.2 mV max after calibration. Similarly, the gain error is ±1% before calibration but can be finely adjusted to ±0.004% of reading once calibrated. These calibration capabilities ensure high accuracy and reliability in measurements.
The SCXI-1200 can output voltages in the range of 0 to +10V and ±5V, suitable for a variety of control and actuation tasks. It is supported by NI-DAQmx driver software, ensuring easy integration with computer systems and
| Specification | Detail |
|---|---|
| Part Number | 182415F-01 |
| Category | SCXI & Legacy |
| Model | SCXI-1200 |
| Description | National Instruments SCXI-1200 Data Acquisition and Control Module |
| Resolution | 12-bit |
| Analog Input Channels | 8 single-ended or 4 differential |
| Input Modes | Referenced single-ended (RSE), Non-referenced single-ended (NRSE), Differential (DIFF) |
| Analog Output Channels | 2 single-ended |
| Analog Input Range | 0 V to 10 V (unipolar), -5 V to +5 V (bipolar) |
| Digital I/O Channels | 32, TTL compatible |
| Overload Protection (Powered On) | ±42 V |
| Overload Protection (Powered Off) | ±15 V |
| Offset Error (Before Calibration) | ±50 mV max |
| Offset Error (After Calibration) | ±0.2 mV max |
| Gain Error (Before Calibration) | ±1% |
| Gain Error (After Calibration) | ±0.004% of reading |
| Voltage Output Range | 0 to +10V, ±5V |
| Driver Software | NI-DAQmx |
| Compatible ADEs | LabVIEW, LabWindows/CVI |
| Connectors | 50-pin male ribbon-cable (front), 25-pin