img

182625-01

The AT-MIO-64E-3 by National Instruments is a legacy DAQ device with a 500 kS/s sampling rate and compatibility with Windows OS.

In Stock | Ships Today

img

    Description

    The AT-MIO-64E-3, with the part number 776911-01, falls under the category of Legacy DAQ Devices. Manufactured by National Instruments, it is part of the 6061E family and is designed to offer robust data acquisition capabilities.

    It is compatible with various software, including LabVIEW, LabWindows/CVI, Measurement Studio, VI Logger, and Traditional NI-DAQ. This device supports operating systems such as Windows 2000/NT/Me/9x, making it versatile for a wide range of applications.

    The AT-MIO-64E-3 boasts impressive sampling rates, offering up to 333 kS/s for multiple channels, 500 kS/s for a single channel, and 1 MS/s for output rate. It provides a significant number of analog inputs, with 64 single-ended or 32 differential channels, alongside two 12-bits analog outputs with a ±10V output range.

    Concerning voltage, the input range is quite flexible, spanning from ±0.05 to ±10 V. Moreover, the device guarantees a high input impedance, marked at 100 GΩ when powered on and a minimum of 820 Ω when powered off.

    Question 1: What is the part number for AT-MIO-64E-3?
    Answer 1: 182625-01 and 776911-01

    Question 2: What software is AT-MIO-64E-3 compatible with?
    Answer 2: LabVIEW, LabWindows/CVI, Measurement Studio, VI Logger

    Question 3: What is the max sampling rate for a single channel on the AT-MIO-64E-3?
    Answer 3: 500 kS/s

    Question 4: How many analog inputs does the AT-MIO-64E-3 support?
    Answer 4: 64 single-ended or 32 differential

    Question 5: What are the AT-MIO-64E-3’s analog output specs?
    Answer 5: Two 12-bits outputs with ±10V range

    Specification Detail
    Part Number 776911-01
    Model AT-MIO-64E-3
    Category Legacy DAQ Devices
    Description CCA, AT-MIO-64E-3
    Manufacturer National Instruments
    Family 6061E
    Software Compatibility LabVIEW, LabWindows/CVI, Measurement Studio, VI Logger, Traditional NI-DAQ
    Operating Systems Windows 2000/NT/Me/9x
    Sampling Rate Up to 333 kS/s (Multiple Channels), 500 kS/s (Single Channel), 1 MS/s (Output Rate)
    Analog Inputs 64 single-ended or 32 differential
    Analog Outputs Two 12-bits, ±10V output range
    Input Voltage Range ±0.05 to ±10 V
    Input Impedance (Powered On) 100 GΩ
    Input Impedance (Powered Off) 820 Ω min