img

182637C-01

The AT-MIO-16DE-10 is a NIST-calibrated, ISA interface DAQ device with 16 AI, 2 AO, 32 DIO, and 2 timers, supporting up to 100 kS/s.

In Stock | Ships Today

img

    Description

    The product with the part numbers 182637C-01, 777640-01, and 184578P-01 falls under the Legacy DAQ Devices category. It is known as the AT-MIO-16DE-10 model, which is a multifunction DAQ device manufactured by National Instruments. This device is part of the E Series, specifically the NI-6021E family, designed to provide a flexible and efficient data acquisition solution.

    The AT-MIO-16DE-10 is compatible with NI-DAQ legacy software, which includes LabVIEW, Measurement Studio, and VI Logger, making it versatile for various applications. It operates on Windows platforms, including Windows 2000, NT, and Me, ensuring broad compatibility with existing systems. The device connects to the computer via an ISA bus interface, which, while older, is suitable for legacy systems that require such connectivity.

    With a maximum sampling rate of 100 kS/s and a resolution of 12-bits, this device offers precise data acquisition capabilities. It features 16 single-ended or 8 differential analog input channels, allowing for flexible data collection from various sensors. Additionally, it includes 2 analog output channels for tasks that require analog signal generation.

    The AT-MIO-16DE-10 is equipped with 32 TTL digital I/O lines, operating at 5V, which can be used for interfacing with external devices, signaling, or digital data acquisition. It also includes 2 timers, with a 24-bits resolution and a 20 MHz frequency, enabling precise timing and control tasks. Finally, the device is NIST-calibrated, ensuring accurate and reliable measurements in professional and industrial environments.

    < Question 1: What is the maximum sampling rate of the AT-MIO-16DE-10?
    Answer 1: 100 kS/s

    Question 2: How many analog input channels does the device have?
    Answer 2: 16 single-ended or 8 differential

    Question 3: What kind of interface does the AT-MIO-16DE-10 use?
    Answer 3: ISA bus interface

    Question 4: Is the AT-MIO-16DE-10 NIST-calibrated?
    Answer 4: Yes

    Question 5: What software is compatible with the AT-MIO-16DE-10?
    Answer 5: LabVIEW, Measurement Studio, VI Logger

    Specification Details
    Part Number 182637C-01, 777640-01, 184578P-01
    Category Legacy DAQ Devices
    Model AT-MIO-16DE-10
    Description National Instruments AT-MIO-16DE-10 Multifunction DAQ
    Family E Series, NI-6021E
    Software Compatibility NI-DAQ legacy (LabVIEW, Measurement Studio, VI Logger)
    Operating Systems Windows (2000/NT/Me)
    Bus Interface ISA
    Maximum Sampling Rate 100 kS/s
    Resolution 12-bits
    Analog Input Channels 16 single-ended or 8 differential
    Analog Output Channels 2
    Digital I/O Lines 32 TTL, 5V
    Timers 2, 24-bits resolution, 20 MHz
    Calibration NIST-calibrated