Description
The product with the part number 182952B-01 falls under the category of Legacy DAQ Devices. It is identified as model DAQPad-MIO-16XE-50, which is a multifunction Data Acquisition (DAQ) device designed by National Instruments. This device is described as a National Instruments DAQPad-MIO-16XE-50 Multifunction DAQ, indicating its versatility and high functionality in various data acquisition tasks.
This device is compatible with multiple operating systems including Windows 2000/XP/NT, Mac OS X, LabVIEW RT, and Linux, ensuring a wide range of application environments can benefit from its use. It is also NIST-Calibrated, providing assurance of its accuracy and reliability in data collection.
When it comes to input capabilities, this device boasts 16 analog input channels, which can be configured as either eight differential or sixteen single-ended inputs, offering flexibility in connection setups. It supports a sampling rate of up to 20 kS/s, allowing for efficient data collection. Additionally, it provides two analog output channels with an output resolution of 12-bits, suitable for a range of output tasks.
The device’s output is compatible with TTL and CMOS logic levels, ensuring it can interface with a wide range of electronic devices. It includes a configuration memory size of 512 words, allowing for the storage of device configurations. Moreover, the minimum supported pulse width is 10 ns, which highlights the device’s capability to work with high-speed signals.
For connectivity, this DAQ device uses two 32-pin female MDR 1284-C rear connectors, facilitating robust and reliable physical connections for data transfer. Furthermore, it requires NI-DAQmx driver software, and for PC use, NI-DAQ 7 is necessary, ensuring users have access to up-to-date software for device operation and data management.
| Specification | Detail |
|---|---|
| Part Number | 182952B-01 |
| Category | Legacy DAQ Devices |
| Model | DAQPad-MIO-16XE-50 |
| Description | National Instruments DAQPad-MIO-16XE-50 Multifunction DAQ |
| Compatibility | Windows 2000/XP/NT, Mac OS X, LabVIEW RT, Linux |
| Calibration | NIST-Calibrated |
| Analog Input Channels | 16 (Configurable as eight differential or sixteen single-ended inputs) |
| Sampling Rate | Up to 20 kS/s |
| Analog Output Channels | 2 |
| Output Resolution | 12-bits |
| Compatibility | TTL, CMOS |
| Configuration Memory Size | 512 words |
| Minimum Supported Pulse Width | 10 ns |
| Data Transfer Connectors | Two 32-pin female MDR 1284-C rear connectors |
| Driver Software | NI-DAQmx, Requires NI-DAQ 7 for PC use |