Description
The VXI Multifunction I/O module, part number 183004-01, is known by its model name VXI-MIO-64E-1. This product is designed solely as a VXI-MIO-64E-1 Board, tailored to meet a variety of user requirements. It supports multiple Input Modes including NRSE (Non-Referenced Single Ended), RSE (Referenced Single Ended), and DIFF (Differential), accommodating various signal types.
In terms of Input Polarities, it offers flexibility with both Unipolar and Bipolar options, ensuring versatility for different signal ranges. The module is capable of a Maximum Sampling Rate of 1.25MS/s, with a precise Resolution of 12 bits. This makes it suitable for high-speed data acquisition while maintaining accuracy.
It boasts 64 Analog Inputs, enabling extensive data collection from multiple sources simultaneously. Additionally, it includes 8 sets of Digital I/O Lines, which are TTL compatible, facilitating easy integration with digital systems. The module is equipped with Two Timers, each offering a 12-bits resolution, which are essential for precise timing functions. These timers utilize the DAQ-STC for enhanced performance.
Compatibility is a key feature of the VXI-MIO-64E-1, supporting a wide range of software including LabVIEW, LabWindows/CVI, Measure, ComponentWorks, Virtual Bench, NI-DAQ developed applications, and VXI plug&play instrument Driver. This ensures that users can leverage the module within various software ecosystems. Moreover, it is SCXI compatible, allowing for signal conditioning and multiplexing, which further enhances its utility in complex setups.
It is important to note that the VX
| Specification | Details |
|---|---|
| Part Number | 183004-01 |
| Category | VXI Multifunction I/O |
| Model | VXI-MIO-64E-1 |
| Description | VXI-MIO-64E-1 Board Only |
| Input Modes | NRSE, RSE, DIFF |
| Input Polarities | Unipolar and Bipolar |
| Maximum Sampling Rate | 1.25MS/s |
| Resolution | 12 bits |
| Analog Inputs | 64 |
| Digital I/O Lines | 8 sets, TTL compatible |
| Timers | Two, 12-bits resolution |
| Timer Functions | Uses the DAQ-STC |
| Software Compatibility | LabVIEW, LabWindows/CVI, Measure, ComponentWorks, Virtual Bench, NI-DAQ developed applications, VXI plug&play instrument Driver |
| SCXI Compatibility | Yes, for signal conditioning and multiplexing |
| Obsolete Status | Announced by National Instruments, available for purchase and repairs by Apex Waves
Question 1: What is the model name of part number 183004-01? Answer 1: VXI-MIO-64E-1 Question 2: How many analog inputs does VXI-MIO-64E-1 have? Question 3: What is the max sampling rate of VXI-MIO-64E-1? Question 4: What resolution do the two timers of VXI-MIO-64E-1 have? Question 5: Is the VXI-MIO-64E-1 SCXI compatible? |