img

183084G-07

The SCXI-1104, part number 776572-04, is a 32-channel, 42V multiplexer with specialized signal conditioning and compatibility requirements.

In Stock | Ships Today

img

    Description

    The SCXI-1104, part number 776572-04, falls under the SCXI & Legacy category and is designed to serve as a 32 Channel 42V-Multiplexer. This device is adept at handling medium-voltage signals, which include 30 VACrms, ±42 VACpeak, and ±60 VDC. It is equipped with a three-pole lowpass filter, featuring a 2 Hz cutoff frequency, ensuring precise signal conditioning and noise reduction for your measurements.

    However, it’s important to note the compatibility constraints, as this module does not support ribbon-cabled multichassis SCXI systems. For such systems, the SCXI-1346 is required. In terms of connectivity options, the SCXI-1104 requires additional devices such as the SCXI-1310, TBX-96, BNC-2095, or SCXI-1300 for optimal operation.

    To leverage the full capabilities of the SCXI-1104, certain software requirements need to be met, including VirtualBench, ComponentWorks, Measure, LabWindows/CVI, and LabVIEW for Windows/Macintosh platforms. Additionally, the NI-DAQ device driver is essential for Macintosh or PC compatibles to ensure seamless integration and functionality.

    This module comes with a 50-pin male ribbon cable back connector and a 96-pin male DIN C front connector, providing versatile connection options for different setups. With dimensions of 4.54 x 10.75 inches, it presents a compact solution for a variety of measurement and testing applications. Moreover, it operates efficiently within a temperature range of 0 to 50 °C, allowing for reliable performance in diverse environments.

    Question 1: What is the voltage capacity of the SCXI-1104?
    Answer 1: 30 VACrms, ±42 VACpeak, ±60 VDC

    Question 2: Does SCXI-1104 support ribbon-cabled multichassis systems?
    Answer 2: No, it requires SCXI-1346.

    Question 3: What software is needed for SCXI-1104 operation?
    Answer 3: VirtualBench, ComponentWorks, Measure, LabWindows/CVI, LabVIEW

    Question 4: What is the cut-off frequency of SCXI-1104’s lowpass filter?
    Answer 4: 2 Hz

    Question 5: What are SCXI-1104’s connection options?
    Answer 5: SCXI-1310, TBX-96, BNC-2095, SCXI-1300

    Specification Detail
    Part Number 776572-04
    Category SCXI & Legacy
    Model SCXI-1104
    Description 32 Channel 42V-Multiplexer
    Signal Conditioning Medium-voltage signals, including: 30 VACrms, ±42 VACpeak, and ±60 VDC
    Filter Three-pole lowpass filter with a 2 Hz cutoff frequency
    Compatibility Does not support ribbon-cabled multichassis SCXI systems. Requires SCXI-1346 for multichassis systems.
    Connectivity Device Requires SCXI-1310, TBX-96, BNC-2095, or SCXI-1300
    Software Requirement VirtualBench, ComponentWorks, Measure, LabWindows/CVI, LabVIEW for Windows/Macintosh
    Device Driver NI-DAQ for Macintosh or PC Compatibles
    Connectors 50-pin male ribbon cable back connector, 96-pin male DIN C front connector
    Dimensions 4.54 x 10.75 in.
    Operating Temperature 0 to 50 °C