img

183084J-01L

The SCXI-1102 model features a 32-channel voltage input, ±42 V overvoltage protection, and a maximum sampling rate of 333 kS/s.

In Stock | Ships Today

img

    Description

    The SCXI-1102, identifiable by part numbers 183084J-01L, 776572-02, and 183087H-01, falls under the SCXI & Legacy category, signifying its compatibility and usage within specialized computing interfaces and legacy systems. This model is designed to facilitate precise data acquisition and signal conditioning in a variety of applications.

    Featuring 32 channels for voltage input, the SCXI-1102 is adept at handling multiple input signals simultaneously, including millivolt, volt, and current ranges of 0 to 20 mA and 4 to 20 mA. This broad range of input signal compatibility ensures versatility across numerous measurement and monitoring tasks.

    With an overvoltage protection of ±42 V, the device ensures safety and durability against unexpected voltage spikes, thereby protecting both the module and the connected systems. The bandwidth capability of the SCXI-1102 is set at 2 Hz, which, when coupled with a maximum sampling rate of 333 kS/s, allows for efficient data capture and analysis.

    For effective operation, the SCXI-1102 requires the integration with SCXI chassis or PXI/SCXI combination chassis, signaling its flexibility and adaptability to various system configurations. Additionally, the inclusion of an SCXI-1600 or E/M Series DAQ Device, a computer (for SCXI chassis configurations), necessary cabling, a cable adapter, and sensors, underscores the comprehensive setup needed for operational deployment.

    Compatibility with multiple terminal blocks, including SCXI-1300, SCXI-1303, SCXI-1308, SCXI-1310, TC-2095, TBX-1303, and TBX-96, further enhances its adaptability, allowing users to tailor their setups based on specific requirements and existing equipment.

    Software support is robust, offering compatibility with NI-DAQmx, LabVIEW, LabWindows/CVI, and Measurement Studio. This broad software support spectrum ensures that users can efficiently program and integrate the SCXI-1102 into their measurement and analysis routines using their preferred development environments.

    The physical connectivity of the SCXI-1102 is facilitated through a 96-pin male DIN C front connector

    Question 1: What is the max overvoltage protection of the SCXI-1102?
    Answer 1: ±42 V

    Question 2: How many input channels does the SCXI-1102 have?
    Answer 2: 32 channels

    Question 3: What is the SCXI-1102’s max sampling rate?
    Answer 3: 333 kS/s

    Question 4: Which chassis is required for the SCXI-1102 operation?
    Answer 4: SCXI or PXI/SCXI combo chassis

    Question 5: Is the SCXI-1102 compatible with LabVIEW software?
    Answer 5: Yes

    Specification Detail
    Part Number 183084J-01L, 776572-02, 183087H-01
    Category SCXI & Legacy
    Model SCXI-1102
    Channels 32-Channel Voltage Input
    Overvoltage Protection ±42 V
    Bandwidth 2 Hz
    Maximum Sampling Rate 333 kS/s
    Input Signals Millivolt, Volt, 0 to 20 mA, 4 to 20 mA
    Compatible Terminal Blocks SCXI-1300, SCXI-1303, SCXI-1308, SCXI-1310, TC-2095, TBX-1303, TBX-96
    Required Components for Operation SCXI chassis or PXI/SCXI combination chassis, SCXI-1600 or E/M Series DAQ Device, Computer (if using SCXI chassis), Cabling, Cable Adapter, Sensors
    Software Support NI-DAQmx, LabVIEW, LabWindows/CVI, Measurement Studio
    Connectors 96-pin male DIN C front connector, 50-pin male ribbon cable rear connector
    Physical Dimensions