Description
The SCXI-1102 is a high-performance Voltage Input Module designed to cater to a wide range of measurement needs. It comes with part numbers 776572-02 and 183087H-01, indicating its unique identification for ordering and support. As a part of the SCXI & Legacy category, this module ensures compatibility and integration with existing systems.
Featuring a 32-Channel configuration, the SCXI-1102 offers extensive data acquisition capabilities. Each channel is equipped with 2 Hz lowpass filtering, ensuring clean signal acquisition free from high-frequency noise. The module’s overvoltage protection is rated at ±42 V, safeguarding the equipment against unexpected voltage spikes.
With a bandwidth of 2 Hz, the SCXI-1102 is optimized for low-frequency applications, delivering precise measurements. The maximum sampling rate achievable by this module is an impressive 333 kS/s, allowing for high-speed data collection across all channels. It supports a variety of signal input types, including Millivolt, Volt, 0 to 20 mA, and 4 to 20 mA, making it versatile for different measurement needs.
Compatibility with multiple terminal blocks, such as SCXI-1300, SCXI-1303, SCXI-1308, SCXI-1310, TC-2095, TBX-1303, and TBX-96, ensures that users have the flexibility to connect various sensors and devices as per their project requirements. To operate, the SCXI-1102 requires an SCXI chassis or PXI/SCXI combination chassis, SCXI-1600 or E/M Series DAQ Device, a computer, cabling, a cable adapter, and sensors.
The module’s software compatibility spans across NI-DAQmx, LabVIEW, LabWindows/CVI, and Measurement Studio, providing users with a range of options for programming and data analysis. This broad compatibility ensures that engineers and
| Specification | Detail |
|---|---|
| Part Number | 776572-02, 183087H-01 |
| Category | SCXI & Legacy |
| Model | SCXI-1102 |
| Type | Voltage Input Module |
| Channels | 32-Channel |
| Lowpass Filtering | 2 Hz for each channel |
| Overvoltage Protection | ±42 V |
| Bandwidth | 2 Hz |
| Maximum Sampling Rate | 333 kS/s |
| Signal Input Types | Millivolt, Volt, 0 to 20 mA, 4 to 20 mA |
| Compatible Terminal Blocks | SCXI-1300, SCXI-1303, SCXI-1308, SCXI-1310, TC-2095, TBX-1303, TBX-96 |
| Required Equipment | SCXI chassis or PXI/SCXI combination chassis, SCXI-1600 or E/M Series DAQ Device, a computer, cabling, cable adapter, sensors |
| Software Compatibility | NI-DAQmx, LabVIEW, LabWindows/CVI, Measurement Studio |
| Connectors |