img

183084L-01

The SCXI-1102 is a 32-channel voltage input module with 2 Hz lowpass filtering, ±42 V overvoltage protection, and a 333 kS/s max sampling rate.

In Stock | Ships Today

img

    Description

    “`html

    The SCXI-1102 is part of the SCXI & Legacy category and comes with various part numbers including 183084L-01, 776572-02, 183087H-01. This model is designed to provide a 32-Channel Voltage Input capability, making it versatile for a wide range of applications.

    Each channel comes with Lowpass Filtering at 2 Hz, ensuring that signal noise is minimized for clearer readings. The SCXI-1102 also features Overvoltage Protection up to ±42 V, protecting the device from unexpected voltage spikes. Its bandwidth is also rated at 2 Hz, matching its lowpass filtering capability.

    When it comes to performance, the SCXI-1102 boasts a Maximum Sampling Rate of 333 kS/s, making it capable of handling high-speed signal processing tasks. It accepts a variety of Signal Inputs, including Millivolt, volt, 0 to 20 mA, and 4 to 20 mA, further emphasizing its versatility.

    Compatible with several terminal blocks such as SCXI-1300, SCXI-1303, SCXI-1308, SCXI-1310, TC-2095, TBX-1303, TBX-96, the SCXI-1102 can be easily integrated into existing setups. For operation, it requires components like an SCXI chassis or PXI/SCXI combination chassis, SCXI-1600 or E/M Series DAQ Device, a computer (for SCXI chassis), cabling, a cable adapter, and sensors.

    Software compatibility is broad, with support for NI-DAQmx, LabVIEW, LabWindows/CVI, Measurement Studio, allowing for flexible programming and data analysis options. Finally, it features a 96-pin male DIN C front connector, facilitating easy and secure connections to other devices and systems.

    “`

    Specification Detail
    Part Numbers 183084L-01, 776572-02, 183087H-01
    Category SCXI & Legacy
    Model SCXI-1102
    Channels 32-Channel Voltage Input
    Lowpass Filtering 2 Hz for each channel
    Overvoltage Protection ±42 V
    Bandwidth 2 Hz
    Maximum Sampling Rate 333 kS/s
    Signal Inputs Millivolt, volt, 0 to 20 mA, and 4 to 20 mA
    Compatible Terminal Blocks SCXI-1300, SCXI-1303, SCXI-1308, SCXI-1310, TC-2095, TBX-1303, TBX-96
    Required Components SCXI chassis or PXI/SCXI combination chassis, SCXI-1600 or E/M Series DAQ Device, computer (for SCXI chassis), cabling, cable adapter, sensors
    Software Compatibility NI-DAQmx, LabVIEW, LabWindows/CVI, Measurement Studio
    Connectors 96-pin male DIN C front connector,

    Question 1: What is the SCXI-1102’s max overvoltage protection?
    Answer 1: ±42 V

    Question 2: How many channels does the SCXI-1102 support?
    Answer 2: 32 channels

    Question 3: What is the SCXI-1102’s maximum sampling rate?
    Answer 3: 333 kS/s

    Question 4: What lowpass filtering does the SCXI-1102 have?
    Answer 4: 2 Hz

    Question 5: Are LabVIEW and NI-DAQmx compatible with SCXI-1102?
    Answer 5: Yes