Description
The SCXI-1104, part number 776572-04, is categorized under SCXI & Legacy products. It is a Voltage Input Module designed for signal conditioning of medium-voltage signals, including 30 VACrms, ±42 VACpeak, and ±60 VDC. This module features a three-pole lowpass filter with a 2 Hz cutoff frequency, ensuring clean signal processing.
The SCXI-1104 supports SCXIbus and is capable of indirect scanning, enhancing its versatility in various applications. For connectivity, it requires devices such as the SCXI-1310, TBX-96, BNC-2095, or SCXI-1300. The module is compatible with a range of software including VirtualBench, ComponentWorks, Measure, LabWindows/CVI for Windows, LabVIEW for Windows, and LabVIEW for Macintosh. Additionally, it requires NI-DAQ drivers either for Macintosh or PC Compatibles to function properly.
Physically, the module measures 4.54 x 10.75 inches, making it compact and easy to integrate into various setups. It operates efficiently within a temperature range of 0 to 50 °C and can be stored in temperatures ranging from –55 to 150 °C. The SCXI-1104 is designed to work in environments with a relative humidity of 5% to 90% (non-condensing).
Despite being announced as obsolete by National Instruments, the SCXI-1104 is still available for purchase and repairs through Apex Waves. Calibration services are available, with options accredited by NIST, and it is recommended to have the module calibrated either annually or every two years. For connection to other devices, it utilizes a 50-pin male ribbon cable.
| Specification | Detail |
|---|---|
| Part Number | 776572-04 |
| Category | SCXI & Legacy |
| Model | SCXI-1104 |
| Description | Voltage Input Module |
| Signal Conditioning | Medium-voltage signals: 30 VACrms, ±42 VACpeak, ±60 VDC |
| Filter | Three-pole lowpass with a 2 Hz cutoff frequency |
| SCXIbus Support | Yes |
| Indirect Scanning | Supported |
| Required Connectivity Device | SCXI-1310, TBX-96, BNC-2095, or SCXI-1300 |
| Software Requirement | VirtualBench, ComponentWorks, Measure, LabWindows/CVI for Windows, LabVIEW for Windows, LabVIEW for Macintosh |
| Driver Requirement | NI-DAQ for Macintosh or NI-DAQ for PC Compatibles |
| Physical Dimensions | 4.54 x 10.75 in. |
| Operating Temperature Range | 0 to 50 °C |
| Storage Temperature Range | –55 to 150 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Obsolete Status | Announced by National Instruments, available for purchase and repairs by Apex Waves |
| Calibration | Available, with NIST accredited options |
| Recommended Calibration Period | Annually or every two years |
| Connectors | 50-pin male ribbon cable